Rev.
6
Oct.18
Proprietary and Confidential - Contents subject to change
165
!DACGPSSTANDALONE
Enter/exit Stand Alone RF mode
Enter or exit stand alone (SA) RF mode.
Requirements:
Before this command can be used:
•
=1 to start the CGPS diagnostic task.
Password required:
Yes (see
for details)
Usage:
•
Execution:
AT!DACGPSSTANDALONE=<state>
Response:
<status>
OK
or
ERROR
Purpose:
Enter or exit Stand Alone RF mode.
Parameters:
<state> (Requested SA RF mode)
•
0—Exit
•
1—Enter
<status> (Return value indicating requested <state> change)
•
Appears only if <state> change is successful.
•
4B0D65001400—Successfully changed state.
!DACGPSTESTMODE
Start/stop CGPS diagnostic task
Start or stop the CGPS diagnostic task. This command allows the GNSS engine to be
tested without obtaining a GNSS position fix.
Password required:
Yes (see
for details)
Usage:
•
Execution:
AT!DACGPSTESTMODE=<mode>
Response:
<status>
OK
or
ERROR
Purpose:
Start or stop the CGPS diagnostic task.
Parameters:
<mode> (Start/stop CGPS diagnostic task)
•
0—Stop
•
1—Start
<status> (Return value indicating requested <mode> change)
•
Appears only if <mode> change is successful.
•
4B0D0800—Successfully started the CGPS diagnostic task
•
4B0D0C00—Successfully stopped the CGPS diagnostic task
Table 6-2: Test Command Details (Continued)
Command