42
simon.es/simon100
INSTALATION AND CONFIGURATION GUIDE
Simon | 100
COMMAND_CLASS_CONFIGURATION
-
CONFIGURATION_GET
o
When you add 10002020-13x or 10002080-13x Simon Devices, some CONFIGURATION_GETS are
performed in order to get a better experience with the Simon 100 iO APP.
o
Once devices are in the Simon 100 iO APP, if you are in a Simon’s device window, you can expand
the advanced settings, HUB iO will request some device CONFIGURATIONS.
-
CONFIGURATION_SET
o
When you add 10002035-13x, 10002021-13x or 10002081-13x Simon Devices, some
CONFIGURATION_SETs are performed in order to get a better experience with the Simon 100 iO
APP.
o
Once devices are in the Simon 100 iO APP, if you are in a Simon’s device window, and you have the
advanced settings visible, you can change some device configurations that will be sent once you
press OK. (If you press identify, a CONFIGURATION_SET is sent performing a fast blink of 5 seconds
on the device).
o
When you remove a Simon Device, the HUB iO will sent a CONFIGURATION_SET with “Reset To
default” Parameter and “Restore default” value to increase the user experience. (The device will
not be removed from the Z-Wave network.
COMMAND_CLASS_METER
-
METER_SUPPORTED_GET
When a device of Home control Group 8 that supports
COMMAND_CLASS_METER
is added, METER_SUPPORTED_GET is sent in order to know the kind of values
that can be reported.
-
METER_GET
if you go into a
device of Home control Group 8 that supports meter command class and
reports KWh
device window, METER_GET of KWh is sent. If device has some channels that reports KWh gets
for these channels will be sent once channels are expanded.
COMMAND_CLASS_SWITCH_BINARY
-
SWITCH_BINARY
_SET
is performed when 10002034-13x or 10002041-13x icon is pressed.
The value will
change between 0 and 255
in order to change the device state
.
It is also performed when an experience is performed sending the value stablished in the experience
settings.
COMMAND_CLASS_SWITCH_MULTILEVEL
-
SWITCH_MULTILEVEL_SET
Sent when a Simon Dimmer 10002020-13x icon is pressed value changes from
0 to 255 in order to change the device state and time is set to default time.
It is also performed when an experience is performed sending the value stablished in the experience
settings.
-
SWITCH_MULTILEVEL_SET (without ACK)
Sent when a Simon Dimmer 10002020-13x is active and user
moves the finger through the icon area (from right to left or left to right) value is set according the “7 LEDs
indicator” and time is set to 0.
-
SWITCH_MULTILEVEL_START_LEVEL_CHANGE (UP)
Sent when a Simon Roller Blind 10002080-13x icon is
pressed on right side.
-
SWITCH_MULTILEVEL_START_LEVEL_CHANGE (DOWN)
Sent when a Simon Roller Blind 10002080-13x
icon is pressed on left side.
-
SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
Sent when a Simon Roller Blind 10002080-13x icon is
pressed after cause an START LEVEL UP or DOWN.