Tally Dascom DT-210/230 Programming Guide V1.1
- 33 -
7 Status Commands
GS a n
[Function]
Enable/disable Automatic Status Back (ASB)
[Format]
ASCII
GS a n
Hex
1D 61 n
Decimal
29 97 n
[Range]
0 ≤ n ≤ 255
[Default]
n = 0 [when DIP switch [SW 2-1] is off.]
n = 2 [when DIP switch [SW 2-1] is on.]
[Description]
• Enables or disables basic ASB (Automatic Status Back).
(n)Bit
Off
/
On
Hex
Decimal
Function
0
Off
00
0
Drawer kick-out connector status disabled.
On
01
1
Drawer kick-out connector status enabled.
1
Off
00
0
Online/offline status disabled.
On
02
2
Online/offline status enabled.
2
Off
00
0
Error status disabled.
On
04
4
Error status enabled.
3
Off
00
0
Roll paper sensor status disabled.
On
08
8
Roll paper sensor status enabled.
4-7
Off
00
0
Reserved.
• While basic ASB is active, the selected enabled basic ASB status is transmitted whenever
the status changes.
• The basic ASB status to be transmitted is the four bytes that follow:
• First byte (printer information)
Bit
Off
/
On
Hex
Decimal
Status
0,1
Off
00
0
Fixed
2
Off
00
0
Drawer kick-out connector pin 3 is LOW.
On
04
4
Drawer kick out connector pin 3 is HIGH.
3
Off
00
0
Online
On
08
8
Offline
4
On
10
16
Fixed
5
Off
00
00
Cover is closed.
On
20
32
Cover is open.
6
Off
00
0
Paper is not being fed with the paper FEED
button.
On
40
64
Paper is being fed with the paper FEED
button
7
Off
00
0
Fixed
Summary of Contents for DT-210