82
PWD:
the device password can be specified using this parameter. The superadmin and admin
passwords are both accepted (default superadmin password: 1234). The
PWD
is an optional
parameter which should be used only when sending commands from phone numbers which are
not configured in the device, or from ones which are configured, but for which other than the
"
Accept call and don’t request password
" option is assigned in the “
Incoming call
management
” section – such phone numbers are considered unauthorized, therefore in this case
the password is required). If the device password is not specified in the control command sent
from unauthorized phone numbers, the command will not be executed by the device.
CRQ
= request confirmation in response SMS (optional parameter, to be used if confirmation is
requested). If this parameter is added to the control command, the device will respond to the
sender by SMS with information regarding the execution of the command.
Commands should always begin with star "
" and end with hash "
#
" character. It is also possible
to send multiple commands in one message, but the message should not exceed 60 characters.
If the response message to be received from the device would exceed 60 characters, only the first
60 characters will be sent. In case of making mistakes in the command, the following response
will be received: "
SYNTAX ERROR!
" and the command(s) will not be executed.
Responses messages sent by the device (when using the CRQ parameter):
Armed
= the device has been armed
Disarmed
= the device has been disarmed
Arming failed
= the device could not be armed
*
Disarming failed
= the device could not be disarmed
*
Relay1 activated: 54 sec.
= output OUT1 activated for 54 seconds
Relay1 activated: Permanent.
= output OUT1 activated permanently (bistable mode)
Relay1 deactivated.
= output OUT1 deactivated
Unauthorized User!
= Wrong or missing password
Examples for command usage:
To activate output OUT1 permanently (bistable mode):
If the command is sent from a phone number for which the "
Accept call and
don’t
request password
" option is selected at incoming call management options and no
confirmation is requested, then the command will be:
R1=ON#
If the command is sent from a phone number for which the "
Accept call and request
password
" or the “
Reject call
” option is selected at incoming call management options,
then device password will also be required, therefore the command will be:
R1=ON, PWD=1234#
(if the superadmin or admin password is 1234)
If the command is sent from a phone number which is not configured in the device and
confirmation is requested, then the command will be:
R1=ON, PWD=1111, CRQ#
Example for module status information sent by the device:
Status information refers to states and values measured in the moment when the device sends
the message!
Z1=R
shows the state of inputs
IN1…IN4/IN6 (
R
=Ready/idle,
A
=Activated)
Z2=A
…
Z6=R
Armed
shows the armed/disarmed status
R1=ON, 37 sec
shows the state of the output OUT1 (
ON
or
OFF
), the remaining time till
deactivation, or “
Permanent
” if it has been activated permanently
RF: 23
shows the GSM signal level from 1 to 31