5.4
Direct Commands From MCU to Reader
5.4.1
Command Codes
Table 5-29. Command Codes
Command Code (hex)
Command
Comments
00
Idle
03
Software Initialization
Software initialization, same as power on reset
0F
Reset
10
Transmission without CRC
11
Transmission with CRC
12
Delayed transmission without CRC
13
Delayed transmission with CRC
14
Transmit next time slot
ISO15693, Tag-It
16
Block receiver
17
Enable receiver
18
Test internal RF (RSSI at RX input with TX ON)
19
Test external RF (RSSI at RX input with TX OFF)
1A
Receiver gain adjust
Note: The command code values from
are substituted in Table 5-32, bit 0 through bit 4. Also,
the most-significant bit (MSB) in
must be set to 1.
5.4.2
Reset
The reset command clears the FIFO contents and FIFO status register (1Ch). It also clears the register
storing the collision error location (0Eh).
5.4.3
Transmission With CRC
The transmission command must be sent first, followed by transmission length bytes, and FIFO data. The
reader starts transmitting after the first byte is loaded into the FIFO. The CRC byte is included in the
transmitted sequence.
5.4.4
Transmission Without CRC
Same as
with CRC excluded.
5.4.5
Delayed Transmission With CRC
The transmission command must be sent first, followed by the transmission length bytes, and FIFO data.
The reader transmission is triggered by the TX timer.
5.4.6
Delayed Transmission Without CRC
Same as above with CRC excluded.
5.4.7
Transmission Next Slot
When this command is received, the reader transmits the next slot command. The next slot sign is defined
by the protocol selection.
5.4.8
Receiver Gain Adjust
This command should be executed when the MCU determines that no TAG response is coming and when