15 |
P a g e
III. Lock Schedule Programming Examples
How to program a basic automatic command for 'Passage mode' on a weekly
schedule
Practical Example: A business wants to schedule the lock to enter passage mode Monday through Friday at
8:30am and return to 'Storehouse mode' at 5:30pm. After 8:30am a valid user can unlock the lock. It will then
stay unlocked until 5:30pm unless a valid user relocks the door. At 5:30pm the lock will automatically relock by
itself. After5:30, valid users can still open the lock, however the lock will automatically relock itself 5 seconds
later to prevent the door from accidentally being left unlocked. (remember, 24 hr time)
Enter: #23456#15#12345#08301730#
#23456#
15#
12345#
0830
1730#
Master Code
Function code
Mon-Fri
Beginning time
Ending time
If the desire is for the lock to be in 'Passage mode' at all times, ' Passage mode' times should be from 12:01am
(0001) to 11:59pm(2359). This is because the lock MUST be in 'Storehouse mode' when the date changes at
midnight each night, if only very briefly. Since the default lock mode is 'Storehouse mode', the 2 minute gap in
the times for 'Passage mode' around midnight allows this to occur.
******************
Practical program to automatically unlock / lock on days at particular times
Practical Example: A business wants to have the lock automatically unlock at 8:00am and relock at 5:00pm
Monday-Friday on a connecting door, without any user intervention. (remember, 24 hr time)
Enter: #23456#63#0800# (automatically unlocks door at 8:00 am)
Enter: #23456#64# (enables auto-unlock feature)
Enter: #23456#67# (enables auto-lock function)
Enter: #23456#15#12345#07591700# (set passage mode start at 7:59am, ending
at 5:00pm)
Note: The reason for 'Passage mode' to start at 7:59am and 'Auto-unlock' to occur at 8:00am is because the
lock must already be in 'Passage mode' before the 'Auto-unlock occurs, otherwise the lock would relock itself 5
seconds later.
The lock needs at least 1 minute between command times. It is not required to use an 'Auto-lock' time
command in this one case, as the lock will lock itself without an 'Auto-lock' command any time it leaves 'Passage
mode' and enters the default 'Storehouse mode'.
******************