INSTALLATION
Series 613
52/149
Edition 12.08.2022
984360EC
Actual Position
10010000
FLOAT
RO
V
[pos]*
0
100
Position State
10100000
UINT8
RO
V
0
2
0:Intermediate
1:Closed
2:Open
Isolation State
10110000
BOOL
RO
NV
0
1
0:Not Isolated
1:Isolated
Homing
Start Condition
10200100
UINT8
RW
NV
0
5
0:Standard
Do homing after restart if valve is not
in sealed state, if it is sealed wait to a
move command (except close
command)
1:Open Command
2:Move Command
3:At Startup
4:Homing Command (Control Mode
Homing)
5:Move Command/Standard
Same as 4:Move Command, but
except close command
End Control Mode
10200300
SINT8
RW
NV
2
5
Control Mode after homing
2:Positon
3:Close
4:Open
5:Pressure Control
End Position
10200400
FLOAT
RW
NV
[pos]*
0
100
Position to End Control Mode 2:
Position
Status
10201100
SINT16
RO
V
0
3
0:Not Started
1:In Progress
2:Completed Successfully
3:Error Occurred
Cycle
Counter
Control Cycles
10300100
UINT32
RW
NV
The valve movement is summarized.
The distance open > close > open is 1
Control Cycle. This value can be
manipulated by the customer (set to 0
after service, for example)
Control Cycles Total
10300200
UINT32
RO
NV
This value is the number of Control
Cycles in valve lifespan.
Isolation Cycles
10300300
UINT32
RW
NV
A Isolation Cycle is done if the valve
has reached the sealed state. This
value can be manipulated by the
customer. (set to 0 after service, for
example)
Isolation Cycles Total
10300400
UINT32
RO
NV
This value is the number of Isolation
Cycle in valve lifespan.
Position
Restriction
Enable
10640100
BOOL
RW
NV
0
1
Limit the valve movement in Control
Mode Pressure, Position, Open,
Interlock Open
Maximum Position
10640300
FLOAT
RW
NV
[pos]*
0
100
Restriction Active
10640400
BOOL
RO
V
0
1
True if the position is currently limited
(Target Position is within the limit)
Position
Adaption
Enable
10660100
BOOL
RW
NV
0
1
Mode
10660200
UINT8
RO
V
1
1
0: Offset
Currently, only the offset mode is
available.
Actual Position
10660300
BOOL8
RW
NV
0
1
0: Real, actual position shows valve
position with added offset value
1: Adapted, actual position shows
valve position without added offset
value
Offset
10660400
FLOAT
RW
NV
[pos]*
0
30
Target Position In
10660500
FLOAT
RO
V
[pos]*
0
100
Same Value as Target Position under
Position Control
Target Position Used
10660600
FLOAT
RO
V
[pos]*
0
100
Target Position In value added with
offset value
Actual Position Real
10660700
FLOAT
RO
V
[pos]*
0
100
Actual Position with offset value
Actual Position
Adapted
10660800
FLOAT
RO
V
[pos]*
0
100
Actual Position without offset value
Sub Group
Parameter
ID [hex]
Data Type Acc
NV
Unit
Min
Max
Descripiton
Oring Pull Out Prevention
Enable
10650100
FLOAT
RW
NV
Only for series 65.3
Delay Homing
10650300
FLOAT
RW
NV
sec
Only for series 65.3
Delay Close
10650400
FLOAT
RW
NV
sec
Only for series 65.3