Series 613
INSTALLATION
984360EC
Edition 12.08.2022
55/149
Sub Group
Parameter
ID [hex]
Data Type Acc NV
Unit
Min
Max Description
General
Settings
Profile Ramp
Enable
07301801
BOOL
RW
NV
0
1
Threshold Mode
07301802
UINT8
RW
NV
0: Actual Pressure
1: Target Pressure Used
Ramp Type
07301840
UINT8
RW
NV
0:Linear
1:Logarithmic
2:Exponential
Actual Slope
07301841
FLOAT
R
-
mbar*/
sec
Controller Selector
Bitmap
07301811
UINT8
RW
NV
0
15
Selects controller which are used the Proifle Ramp
Segment Selector
Bitmap
07301810
UINT8
RW
NV
0
1023 Selects segments which are used in the profile
Segment x Threshold
07301820
FLOAT
RW
NV mbar*
Defines the upper limit of a segment
10 Segments are available
Segment x Slope
07301830
FLOAT
RW
NV mbar*/
sec
Define the slope in the segment
Adaptive
Learn
Start Learn
07501000
BOOL
RW
V
0
1
Start learn procedure by setting to 1
Bank Selection
07500200
SINT8
RW
NV
0
3
Select a learn bank to safe the data for the following
learn procedure
0:Bank 1
1:Bank 2
2:Bank 3
3:Bank 4
Pressure Limit [SFS]
07500300
FLOAT
RW
NV
SFS 0.0001
1.2
Learn procedure will be executed to the Pressure
Limit
Pressure Limit
07500800
FLOAT
RW
NV mbar*
See Pressure Limit [SFS] above, same functionality
but user pressure scalin
g
is used
Open Speed
07500400
FLOAT
RW
NV
0.001
1
1.0 equals to full speed
Status
07500600
SINT8
RO
V
0
4
0:Not Started
1:In Progress
2:Completed Successfully
3:Aborted
4:Failed
Warning Info
07500700
UINT16
RO
V
Bit 1: Checksum error
Bit 2: Terminated by user
Bit 3: Unsuitable learn condition / pressure too high
Bit 4: Unsuitable learn condition / pressure too low
Bit 5: Pressure decreasing instead of rising
Bit 6: Open pressure does not match
Learn Bank 1
xx = 11
Learn Bank 2
xx = 12
Learn Bank 3
xx = 13
Learn Bank 4
xx = 14
Status
0750xx01
SINT8
RO
NV
0
2
0:Not used
1:Avaialable
2:Available with warnings
Data
0750xx02
UINT32
RW
NV
To copy learn data copy this content to another
bank (or valve)
Warning Info
0750xx09
UINT16
RO
NV
Bit 1: Checksum error
Bit 2: Terminated by user
Bit 3: Unsuitable learn condition / pressure too high
Bit 4: Unsuitable learn condition / pressure too low
Bit 5: Pressure decreasing instead of rising
Bit 6: Open pressure does not match
Type
0750xx0A
SINT8
RO
NV
0
2
0:Standard
1:Short
2:Calculated
Delete Learn Bank
Data
0750xx0F
BOOL
RW
V
0
1
Set to 1 delete learn bank data.