VC series bench scales Technical Manual
- 20 -
8.4.7
Data setting
Command
Contents
Parameter
Response
C1
C2
Code
Address Value
C
A
43H 41H
Unit weight
value setting
Nil
Unit
weight
value
A00:Proper completion
E10:Set value is lighter than the
countable unit weight
L
A
4CH 41H
Lower limit
value setting
Lower
limit
value
A00: Proper completion
E02:Value is not an integer
L
B
4CH 42H
Upper limit
value setting
Upper
limit
value
A00: Proper completion
E02:Value is not an integer
8.4.8
Limit function check
Command
Contents
Parameter
Response
C1 C2
Command
Address Value
L
9
4CH 39H Quantity limit
function is
checked if it is
worked
properly.
Nil
Nil
A00:Proper completion
E12:Limit function is not worked
8.4.9
Command sample
① T△
(CR)(LF)
Tare
② O1
(CR)(LF)
Setting constant output *1
③ O0
(CR)(LF)
Stopping output
④ O8
(CR)(LF)
Outputting data *1
⑤ W1
(CR)(LF)
Output weight value
⑥ C1
(CR)(LF)
Output quantity value
⑦ C2
(CR)(LF)
Output unit weight value
⑧ CA,12.34567
(CR)(LF)
Set unit weight 12.34567g.
⑨ LA,+0001000
(CR)(LF)
Set Lower limit
value as +1000pcs.
⑩ L9
(CR)(LF)
Check if limit function works.