PARAMETER NAME
INTERFACE
ACCESS
VISIBILITY
RANGE
DEFAULT
LUTEnable
IBoolean
R/W
E
False/No
True/Yes
False/No
LUTIndex
IInteger
R/W
E
0 to 1023
0
LUTValue
Iinteger
R/W
E
0 to 1023
0
LUTStart
Icommand
W
E
LUTEnd
Icommand
W
E
User set (ICategory: UserSetControl)
6.8
Two defined sets are available in the camera: A (factory) Default set and a UserSet1. Both can be
loaded at any time, by selecting the right set with UserSetSelector and executing UserSetLoad.
Once the UserSet1 is selected (with UserSetSelector), the present configuration may be saved into the
set by executing UserSetSave.
In the Default set cannot be saved by the user.
PARAMETER NAME
INTERFACE
ACCESS
VISIBILITY
RANGE
DEFAULT
UserSetSelector
IEnumera-
tion
R/W
B
Default
UserSet1
UserSet1
UserSetLoad
ICommand
W
B
UserSetSave
ICommand
W
B
Built In Test (ICategory: Adimec)
6.9
A built In Test (BIT) function in the camera verifies functions and signals critical errors when they arise.
Some tests are run at camera start-up and others are continuously run.
The build in test result is readable. If no failure is detected, it returns value 0. Each failure condition
has a non-zero associated BIT return value, listed in table 6.5.
For any BIT value other than 0 or 128, contact your local support.
BIT RETURN
DESCRIPTION
0
All tests are passed
1
FPGA boot failed
2
FPGA not running
4
Configuration data corrupt
8
Setting data corrupt
128
Output look-up table data corrupt. This requires reprogramming of the LUT (see section 6.7).
256
Sensor data alignment error
BIT return values.
Table 6.5:
PARAMETER NAME
INTERFACE
ACCESS
VISIBILITY
RANGE
DEFAULT
BuiltInTest
IInteger
R
E
See table 6.5
0