BH8-Series – User’s Manual
support@barrett.com
www.barrett.com
© 2007 Barrett Technology®, Inc.
Document: D3000, Version: AF.00
Page 23 of 82
Command:
FGET
Name:
Finger Get
Purpose:
Gets and prints the given parameter(s)'s value(s) for the selected motor(s). Each
parameter has its value(s) printed on one line, with one value for each selected
motor separated by spaces.
Arguments:
<parameterName>
Example:
SFGET DS DP
Notes:
You can get more than one parameter value by listing more than one parameter
name.
Command:
FLOAD
Name:
Finger Load
Purpose:
Loads the selected motor(s)'s parameters from non-volatile storage. This is done
whenever the firmware starts up.
Arguments:
(none)
Example:
3FLOAD
Notes:
The non-volatile storage used does not depend on the super capacitor, so it
retains its value even if the firmware is lost.
Command:
FSAVE
Name:
Finger Save
Purpose:
Saves the selected motor(s)'s parameters to non-volatile storage.
Arguments:
(none)
Example:
123FSAVE
Notes:
The non-volatile storage used does not depend on the super capacitor, so it
retains its value even if the firmware is lost. However, this command should not
be performed more than 5,000 times or the Hand electronics may need repair.
Command:
FDEF
Name:
Finger Default
Purpose:
Sets the selected motor(s)'s parameters back to their factory default values.
Arguments:
(none)
Example:
SFDEF
Notes:
Does not save the changed values to non-volatile storage.
Command:
FLIST
Name:
Finger List
Purpose:
Lists all of the standard motor parameters and their descriptions.
Arguments:
(none)
Example:
FLIST
Notes:
Does not take a motor prefix.
Command:
FLISTV
Name:
Finger List Value
Purpose:
Lists the motor-parameter values for the selected motor(s). Each parameter has
its value(s) printed on one line, with one value for each selected motor separated
by spaces.
Arguments:
(none)
Example:
3FLISTV
Notes:
5.2.3
Global parameter commands
Global parameter commands configure the hand as a whole, without referencing a particular finger
or motor. Except for not taking a motor prefix they are identical to the set of motor parameter
commands. See section 5.4 for a complete list of global parameters.