2–10
ADD RAIDSET
ADD RAIDSET
Creates a RAIDset from 3 to 14 disks.
Format
ADD RAIDSET
RAIDset-name disk-name1 disk-name2 [disk-nameN]
Parameters
RAIDset-name
Specifies a name for the RAIDset. You use this name with the
ADD UNIT
command to
identify the RAIDset as a host-addressable unit.
The name must start with a letter (A–Z) and can then consist of up to eight more
characters made up of letters A-Z, numbers 0-9, periods (.), dashes (-), or underscores (_),
for a total of nine characters.
disk-name1 disk-name2 disk-nameN
The disks that will make up the RAIDset. A RAIDset can contain 3 to 14 member disks.
Switches
POLICY=BEST_FIT
POLICY=BEST_PERFORMANCE (Default)
NOPOLICY
The
POLICY
switch allows you to set the criteria the controller uses to choose a replacement
member from the spareset when a RAIDset member fails.
Select
BEST
_
FIT
to choose a replacement device from the spareset that most closely
matches the capacities of the remaining members. If more than one device in the spareset
is the correct size, the controller selects the device that gives the best performance.
Select
BEST
_
PERFORMANCE
to choose a replacement device from the spareset that results in
the best performance (the device should be on a different port than existing members). If
more than one device in the spareset has the best performance, the controller selects the
device that most closely matches the size of the remaining members.
Select
NOPOLICY
to prevent the controller from replacing a failed disk drive. This causes
the RAIDset to run in a reduced state until a
BEST
_
FIT
or
BEST
_
PERFORMANCE
policy is
selected, or a member is manually replaced in the RAIDset (see
SET
RAIDset-name).
RECONSTRUCT=NORMAL (Default)
RECONSTRUCT=FAST
The
RECONSTRUCT
switch allows you to set the speed at which the controller reconstructs
the data on a new RAIDset member that has replaced a failed member.
Summary of Contents for HSZ40
Page 6: ......
Page 24: ...2 12 ADD RAIDSET See also ADD UNIT DELETE SET RAIDSET SHOW RAIDSET INITIALIZE ...
Page 101: ...HSZ40 Array Controller CLI Reference Manual Glossary ...
Page 112: ......