PIDC0F4: SAFETY DELAY
Delay time for sensor evaluation
The sensor delay time can be activated to delay sensor rela-
ted action. Thus it will be possible to trigger a relay and to di-
sable the output again as soon as the sensor is trioggered.
This allows to create applications like automatic filling stations
(relay activated and de-activated as soon as sensor reports fil-
ling level) or flame detectors (process started but halted if
sensor not in range after delay time).
Delay time is defined in increments of 25ms. Thus the total
time can be adjusted from 0...6,3 seconds.
Parameter: <Slot number> <DELAY> [Byte]
where:
Slot number = $0001:
Slot no. 1
Slot number = $0002:
Slot no. 2
Slot number = $FFFF:
all
DELAY = $00 (000) ... $FF (255)
(timecount * 25ms)
Example: The saftey supersision for relay 2 shall be engaged
after 2 seconds:
SET PID C0F4:
00 02 50
Calculation: 2 seconds is 80x 25ms, 80(dec) is 50 hex ($50). Most RDM
controllers require values to be entered in hex format.
More RDM Info
For more information on DMX RDM pls check the web pages of the DMX RDM protocol group
(www.rdmprotocol.org), or visit: www.rdm.soundlight.de
Disturbances
If a trouble-free operation cannot be guaranteed, disconnect the relay card interface and secure it
against unwanted operation. This is especially necessary, when
- the unit has visible damages;
- the unit does not operate;
- internal parts are loose;
- connection cables show visible damages.
Limited Warranty
This DMX interface ist warranted against defects in metarials and workmanship for a period of 12
month, beginning with the date of purchase. The warranty is limited to repair or exchange of the