Appendix 2
MAN_105G_1.16
Page 160
Status
[Message]
All data correct.
In the above example:
•
A byte is read from the Fieldbus IN area, at byte address 0003h
•
The module performs a logical <data> AND 7Fh.
•
If the result is larger than 20h, the email message is sent to
support@elprotech.com
Note:
If the [Register] or [Register match] information is changed, a reset is required
for changes to take effect. Other changes will take effect directly without a reset.
Note:
Hexadecimal values must be written in the format 0xN where ‘N’ is the
hexadecimal value.
SSI in Email Messages
For predefined emails it is possible to include data in the mails. This is done in a similar way
as data is added to web pages with SSI includes. Due to natural reasons, some SSI functions
cannot be used in email messages.
The supported SSI commands for emails are:
•
DisplayIP
•
DisplaySubnet
•
DisplayGateway
•
DisplayDNS1
•
DisplayDNS2
•
DisplayHostName
•
DisplayDomainName
•
DisplayEmailServer
•
DisplaySMTPUser
•
DisplaySMTPPswd
•
DisplayDhcpState
•
DisplayDhcpSupport
•
printf
•
IncludeFile
•
SsiOutput