/nasmcd/sbin/navicli -h <SPA_IP_Address> storagegroup -list -gname
"
~filestorage"
Example:
# /nasmcd/sbin/navicli -h 10.6.4.126 storagegroup –list –gname "~filestorage"
Storage Group Name: ~filestorage
Storage Group UID: 3E:86:BB:3D:70:64:DF:11:9C:6F:00:60:16:36:9C:7D
HBA/SP Pairs:
HBA UID SP Name SPPort
------- ------- ------
50:06:01:60:BC:E0:08:9F:50:06:01:61:3C:E0:08:9F SP B 0
50:06:01:60:BC:E0:08:9F:50:06:01:69:3C:E0:08:9F SP B 1
50:06:01:60:BC:E0:08:9F:50:06:01:60:3C:E0:08:9F SP A 0
50:06:01:60:BC:E0:08:9F:50:06:01:68:3C:E0:08:9F SP A 1
HLU/ALU Pairs:
HLU Number ALU Number
---------- ----------
0 0
1 1
2 2
3 3
4 4
5 5
16 16
17 17
Shareable: YES
Task 10: Configure the HBA/Initiator Records
The replacement BE contains a new midplane that is assigned different identifiers than were assigned to
the midplane in the faulted BE.
To configure the HBA/Initiator records maintaining the connections running from the replacement BE to the
storage array or switch:
Set up the replacement BE
Remove the old initiator records
Collect the new WWNs
Recreate the initiator records
Verify the new connections
Configure the Blades
Test the functionality of the system
Set Up the Replacement BE
1. [ ] Add the replacement BE to the database, and set up the enclosure ID on the backplane by issuing:
#
/nasmcd/sbin/setup_enclosure -addEnclosure <Blade_enclosure_ID>
Note:
If the
setup_enclosure -addEnclosure
command fails, use the
setup_enclosure
-checkCable
and
setup_enclosure -checkSystem
commands to identify the reason for the failure.