59
Command
Argument
Function
Description
NET
0 – 1
Set Network Mode Activate RS232 multiplex mode for network operation.
0: No network operation, single drive on an RS232
1: Network operation activated
BAUD
Value
Select baud rate
Specify transfer rate for RS232 interface
For value, see chapter 3.6 "Baud rate and node number"
NODEADR
Value
Define Node Ad-
dress
Set node number
Value: 0…255
COMPATIBLE 0 – 1
Set Compatible
Mode
Sett compatibility with previous models
0. Compatibility mode disabled
1: Compatibility mode enabled
ANSW
0 – 7
Answer Mode
0: No asynchronous responses
1: Allow asynchronous responses
2: All commands with confirmation and asynchronous responses
3: Debug mode, sent commands are returned (cannot be used if config-
uring with Motion Manager!)
4-7: analogous to 0-3, but responses resulting from a command in the
sequence program are not sent (cannot be set via Motion Manager)
5.1.3 General parameters
Command
Argument
Function
Description
LL
Value
Load Position
Range Limits
Load limit positions (the drive cannot be moved out of these limits).
Positive values specify the upper limit and negative values the lower.
The range limits are only active if APL1 is.
Value: -1,8 · 10
9
…+1,8 · 10
9
APL
0 – 1
Activate / Deacti-
vate Position Limits
Activate range limits (LL)
(valid for all operating modes except VOLTMOD).
1: Position limits activated
0: Position limits deactivated
SP
Value
Load Maximum
Speed
Load maximum speed. Setting applies to all modes (rpm).
Value: 0 to 30 000
AC
Value
Load Command
Acceleration
Load acceleration value (r/s
2
).
Value: 0…30 000
DEC
Value
Load Command
Deceleration
Load braking value (r/s
2
).
Value: 0…30 000
SR
Value
Load Sampling
Rate
Load sampling rate of the velocity controller as a multiplier of 100 μs
(ms/10).
Value: 1…20
POR
Value
Load Velocity Pro-
portional Term
Load velocity controller amplification.
Value: 1…255
I
Value
Load Velocity Inte-
gral Term
Load velocity controller integral term.
Value: 1…255
PP
Value
Load Position Pro-
portional Term
Load position controller amplification.
Value: 1…255
PD
Value
Load Position Dif-
ferential Term
Load position controller D-term.
Value: 1…255
CI
Value
Load Current Inte-
gral Term
Load integral term for current controller.
Value: 1…255
LPC
Value
Load Peak Current
Limit
Load peak current (mA).
Value: 0…12 000
LCC
Value
Load Continuous
Current Limit
Load continuous current (mA).
Value: 0…12 000
DEV
Value
Load Deviation
Load maximum permissible deviation of actual velocity from target
velocity (deviation)
Value: 0…30 000
CORRIDOR
Value
Load Corridor
Window around the target position.
Value: 1…32 767
5 Parameter description
5.1 Basic setting commands