25
GATEWAY SPECIFICATION - WebdynPulse
WebdynPulse – Gateway specification - Version 2.0
Example:
Configuration:
Connection_Period=7
Connection_Minute=25
Connection time:
Day d: 00:25, 07:25, 14:25, 21:25.
Day d+1: 00:25, 07:25, 14:25, 21:25.
6.4.3 Automatic connection at fixed times
Automatic connection at fixed times consists of programming the WebdynPulse with up to 5 times
for connecting to the remote server per day.
This mechanism is taken into account only if the variable “Connection_Period” is equal to 0.
Programming the connection times is carried out by updating the variables listed below in the
configuration file
prefixID
_var.ini.
Variable
Definition
Default value
Connection_Period
Period for connection to the remote FTP server (in
hours, range 0 to 23)
If >0: number of hours between two connections. The
variable “Connection_Minute” is used to specify the
minute number within the hour for the connection.
If =0: connection every day at the time specified by
the variables “Connection_Hour” and
“Connection_Minute”
0
Connection_Hour
Hour for connection to the remote FTP server
1
Connection_Minute
Minute for connection to the remote FTP server
0
Variable
Definition
Default
value
Connection_Hour
Hour for connecting to remote FTP server
1
Connection_Minute
Minute for connecting to remote FTP server
0
Connection_Hour1
Hour for connecting to remote FTP server
0
Connection_Minute1
Minute for connecting to remote FTP server
0
Connection_Hour2
Hour for connecting to remote FTP server
0
Connection_Minute2
Minute for connecting to remote FTP server
0
Connection_Hour3
Hour for connecting to remote FTP server
0
Connection_Minute3
Minute for connecting to remote FTP server
0
Connection_Hour4
Hour for connecting to remote FTP server
0
Connection_Minute4
Minute for connecting to remote FTP server
0