174
ifm
Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
STATUS_F_V_EXT
19737
260
Unit type = program (PRG)
Unit is contained in the library
ifm_CR0431_util_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
19739
The program STATUS_F_V_EXT determines the status of the fuse for the potential V_EXT.
The calculation basis is the measured VBBs value: SUPPLY_VOLTAGE_VBBS.
voltage measured on the fuse ...
STAT_FUSE ...
exceeds 70 % of VBBs
changes to TRUE
falls below 30 % of VBBs
changes to FALSE
>
Parameters of the inputs
19740
Parameter
Data type
Description
STAT_FUSE
BOOL
Status of the fuse:
TRUE
= OK
FALSE
= failled or not plugged in