176
ifm
Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
OUTPUT
8078
Unit type = function block (FB)
Unit is contained in the library
ifm_CR0431_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
19721
OUTPUT assigns an operating mode to an output channel (
→ data sheet). The FB enables the status
detection on the selected output channel.
The measurement and the output value result from the operating mode indicated via MODE:
• binary output, plus switching (BH)
>
Parameters of the inputs
19707
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
execute this function element
FALSE:
unit is not executed
> Function block inputs are not active
> Function block outputs are not specified
CHANNEL
BYTE
Number of the output channel
0...5 for the outputs K00...K05
6...12 for the outputs LED00...LED06
VALUE
BOOL
TRUE:
activate output
FALSE:
deactivate output
MODE
BYTE
Operating mode of the function block:
0 = 0x00 = off
2 = 0x02 = binary output plus switching
FILTER
BYTE
only for outputs with current feedback:
filter for the measurement on the output:
valid = 0...8 recommended = 4
→ chapter
Configure the software filters of the outputs
(→ p.
For outputs without current feedback:
FILTER = 0 or: do not set the parameter FILTER!
.
The operating mode should not be changed during operation.
Summary of Contents for BasicController CR0431
Page 228: ...228 10 Notizen Notes Notes...