Setting range
Default value
Description
Configure analog control settings.
Analog All
Analog All
Select the gain to configure.
Gain
x1.0 to x16.0
x1.0
Set the gain value for the gain setting
selected in [GainSelector].
Digital All
Digital All
Select the black level to configure.
Black Level
-133 to 255
0
Set the black level value.
Off, Continuous
Off
Enable/disable gain auto adjustment.
Setting range
Default value
Description
Configure settings for digital input/output.
Line2,
Line3,
Line5,
TimeStampReset,
Nand0_In_1,
Nand0_In_2,
Nand1_In_1,
Nand1_In_2
Line2
Select the input/output to configure.
Line Source
Low, High,
Acquisitiion Trigger Wait,
Acquisition Active,
Frame Trigger Wait,
Frame Active,
Exposure Active,
JAIFVAL, JAILVAL,
UserOutput0, UserOutput1,
OptIn1,
JAIPulseGenerator0,
Nand0, Nand1,
Low
Select the line source signal for the item
selected in [LineSelector].
Line Inverter
True, False
False
Enable/disable polarity inversion for the
selected input signal or output signal.
Line Status
True, False
ー
Display the status of the input signal or
output signal (True: High, False: Low).
Line Mode
Input, Output
ー
Display the input/output status (whether it
is input or output).
Line Format
ー
Opto Coupled
Display the signal format.
ー
0x0
Display the input/output signal status.
The state is shown with 16 bits. Bit
assignments are as follows.
[0] (unused)
[1] Line2 - OptOut1
[2] Line3 - OptOut2
[3] (unused)
[4] Line5 - Opt In 1
[5], [6], [7], [8], [9], [10] (unused)
[11] Time Stamp Reset
[12] NAND Gate 0 In 1
[13] NAND Gate 0 In 2
[14] NAND Gate 1 In 1
[15] NAND Gate 1 In 2
User Output 0
User Output 1
User Output 0
Set the UserOutput signal.
User Output Value
True, False
False
Set the value for the UserOutput selected
in [UserOutputSelector].
e) Analog Control
Item
User Output Selector
Line Status All
f) Digital I/O control
Item
Line Selector
Gain Selector
GainAuto
Black Level Selector
—
4
8
—
GO-5100MP-PGE