appears.
3. Run diagnostics on the caching module:
sldiag device run -dev fcache
4. Verify that no hardware problems resulted from the replacement of the caching module:
sldiag device
status -dev fcache -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status of
failures resulting from testing the component.
1. Proceed based on the result of the preceding step:
If the system-level
diagnostics tests…
Then…
Were completed without
any failures
a. Clear the status logs:
sldiag device clearstatus
b. Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit Maintenance mode:
halt
The controller displays the LOADER prompt.
d. Boot the controller from the LOADER prompt:
bye
e. Return the controller to normal operation:
If your controller is in an HA pair
, perform a give back:
storage
failover giveback -ofnode
replacement_node_name
Note:
If you disabled automatic giveback, re-enable it with the
storage
failover modify
command.
If your controller is in a stand-alone configuration
, proceed to the next
step. No action is required.
You have completed system-level diagnostics.
47