RDAIRPABPSI5UG , Rev. 2.0
Freescale Semiconductor
31
Installing the Software and Setting up the Hardware
•
Asbc_SafingOffsetErr - safing offset error
•
Asbc_SafingMode - safing mode status
•
Asbc_SafingDataCount - number of digital sensor messages received with valid sensor data
•
Safing threshold settings - these parameters are returned the same values as described in the initialization function
•
ASBC_Init
Parameters of the Asbc_SetAnlMuxSource API function:
•
Spi_Channel (Asbc_SpiChannelType) - logical SPI channel number (not physical SPI channel)
•
Source (Asbc_AnlMuxSourceType) input parameter - analog source which will be connected to the MUX input
Parameters of the Asbc_SetDcsMuxSource API function:
•
Spi_Channel (Asbc_SpiChannelType) - logical SPI channel number (not physical SPI channel)
•
Source (Asbc_DcsMuxSourceType) input parameter - sensor channel selection determines which DC sensor input shall
be connected for diagnostics output
•
Voltage (Asbc_DcsMuxSourceType) input parameter - bias voltage selection determines which regulated voltage shall
be used as a bias supply on the DC sensor output stage for diagnostics
Parameters of the Asbc_SetSafingMode API function:
•
Spi_Channel (Asbc_SpiChannelType) - logical SPI channel number (not physical SPI channel)
•
SafingMode (Asbc_SafingModeRequestType) input parameter - safing mode request
•
SafingTestEnable (Asbc_SafingTestEnableType) input parameter - safing test enable
•
SafingLevel (Asbc_SafingLevelType) input parameter - arming output level
Parameters of the Asbc_SetVregMode API function:
•
Spi_Channel (Asbc_SpiChannelType) - logical SPI channel number (not physical SPI channel)
•
Config (Asbc_VregConfigType) input configuration parameter - configuration of the ASBC voltage regulator:
•
Asbc_VregSyncSupply (Asbc_VregConfigType) input parameter - Sync supply control
•
Asbc_VregBoost (Asbc_VregBoostType) input parameter - Boost regulator control
•
Asbc_VregBuck (Asbc_VregBuckType) input parameter - Buck regulator control
•
Asbc_VregEnergyReserve (Asbc_VregEnergyReserveType) input parameter - energy reserve control
Parameters of the Asbc_GetVregStatus API function:
•
Spi_Channel (Asbc_SpiChannelType) - logical SPI channel number (not physical SPI channel)
•
VregEnergyReserveTest (Asbc_VregEnergyReserveTestType) input parameter - energy reserve test diagnostic control
•
Status (Asbc_VregStatusType) output structure containing the status of the ASBC voltage regulators:
•
Asbc_VregBoost (Asbc_VregStatBoostType) - report boost voltage less/greater than threshold (~80% of target)
•
Asbc_VregChargDischarFault (Asbc_VregStatChargDischarFaultType) - CER charge/discharge switch failure
status
•
Asbc_VregSyncSupply (Asbc_VregSyncSupplyType) - Sync supply status
•
Asbc_VregBoostEnable (Asbc_VregBoostType) - Boost regulator status
•
Asbc_VregBuckEnable (Asbc_VregBuckType) - Buck regulator status
•
Asbc_VregEnergyReserve (Asbc_VregEnergyReserveType) - energy reserve status
•
Asbc_VregEnergyReserveValue (unit8) - energy reserve test diagnostic status