background image

B – Command Line Interface

Test Command

59225-00 B

B-91

A

Test Command

Tests ports using internal (SerDes level), external (transceiver), and online 
loopback tests. Internal and external tests require that the port be placed in 
diagnostic mode. Refer to the 

“Set Command” on page B-37

 for information about 

changing the port administrative state. While the test is running, the remaining 
ports on the switch remain fully operational.

Authority

Admin session

Syntax

test

port [port_number] [test_type]
cancel
status

Keywords

port [port_number] [test_type]

Tests the port given by [port_number] using the test given by [test_type]. If you 
omit [test_type], Internal is used. [test_type] can have the following values:

internal

Tests the SerDes for all port speeds independent of the capabilities of the 
transceiver. This is the default. The port must be in diagnostics mode to 
perform this test.

external

Tests both the SerDes and transceiver for all port speeds that are supported 
by the transceiver. The port must be in diagnostics mode to perform this test, 
and a loopback plug must be installed in the transceiver.

online

Tests communications between the port and its device node or device loop 
at the operating port speed. The port being tested must be online and 
connected to a remote device. The port passes if the test frame that was 
sent by the ASIC matches the frame that is received. This test does not 
disrupt communication on the port.

cancel

Cancels the online test in progress.

status

Displays the status of a test in progress, or if there is no test in progress, the 
status of the test that was executed last.

                                                                                           

Summary of Contents for SANbox 1400 Series

Page 1: ...S i m p l i f y R 59225 00 B Page i SANbox 1400 Series Fibre Channel Switch Installation Guide Firmware Version 5 0...

Page 2: ...surfer Switch Manager SANsurfer Management Suite and Multistage are trademarks or registered trademarks of QLogic Corporation General Devices is trademark of General Devices Company Inc Gnome is a tra...

Page 3: ...tement 1 5 1 6 5 VCCI Class A Statement 1 6 1 7 Laser Safety Information 1 6 1 8 Electrostatic Discharge Sensitivity ESDS Precautions 1 6 1 9 Accessible Parts 1 7 1 10 Pi ces Accessibles 1 7 1 11 Zug...

Page 4: ...pplet 2 9 2 5 3 Command Line Interface 2 10 2 5 4 SANsurfer Switch Manager Application Programming Interface 2 10 2 5 5 Simple Network Management Protocol 2 10 2 5 6 File Transfer Protocol 2 10 Sectio...

Page 5: ...CLI to Install Firmware 4 22 Section 5 Diagnostics Troubleshooting 5 1 Chassis Diagnostics 5 1 5 1 1 Input Power LED Is Extinguished 5 2 5 1 2 System Fault LED Is Illuminated 5 2 5 2 Power On Self Te...

Page 6: ...B 2 B 3 Working with Switch Configurations B 2 B 3 1 Modifying a Configuration B 3 B 3 2 Backing up and Restoring Switch Configurations B 4 B 4 Commands B 6 Admin Command B 8 Alias Command B 9 Config...

Page 7: ...Command B 91 Uptime Command B 94 User Command B 95 Whoami Command B 98 Zone Command B 99 Zoneset Command B 103 Zoning Command B 106 Glossary Index List of Figures Figure Page 2 1 SANbox 1400 Fibre Ch...

Page 8: ...faults B 32 B 4 Port Configuration Defaults B 33 B 5 Port Threshold Alarm Configuration Defaults B 34 B 6 Zoning Configuration Defaults B 35 B 7 SNMP Configuration Defaults B 35 B 8 System Configurati...

Page 9: ...l user controls and connections Section 3 describes the factors to consider when planning a fabric Section 4 explains how to install and configure the switch Section 5 describes the diagnostic methods...

Page 10: ...y Guide v3 0 This PDF document can be downloaded at http www qlogic com interopguide info asp inter Fibre Channel Arbitrated Loop FC AL 2 Rev 6 8 Fibre Channel 10 bit Interface Rev 2 3 Definitions of...

Page 11: ...shinweise Ein Warnhinweis weist auf das Vorhandensein einer Gefahr hin die m glicherweise Verletzungen zur Folge hat 4 3 4 17 Ein Vorsichtshinweis weist auf das Vorhandensein einer Gefahr hin die m gl...

Page 12: ...erference in which case the user will be required to correct the interference at their own expense Neither the provider nor the manufacturer is responsible for any radio or television interference cau...

Page 13: ...tandards EN60950 2000 Safety of Information Technology Equipment EN60825 1 A2 2001 Safety of Laser Products Part 1 EN55022 1998 Limits and Methods of Measurement of Radio Interference Characteristics...

Page 14: ...ptical transceivers to communicate over the fiber optic conductors The U S Department of Health and Human Services DHHS does not consider Class 1 lasers to be hazardous The International Electrotechni...

Page 15: ...ssibles Les pi ces rempla ables Field Replaceable Units FRU du commutateur SANbox 1400 Series Fibre Channel Switch sont les suivantes Alimentation de courant Interfaces aux media d interconnexion appe...

Page 16: ...our freedom to share and change it By contrast the GNU General Public License is intended to guarantee your freedom to share and change free software to make sure the software is free for all its user...

Page 17: ...on follow 1 12 2 Terms And Conditions For Copying Distribution And Modification 1 This License applies to any program or other work which contains a notice placed by the copyright holder saying it may...

Page 18: ...rmally print such an announcement your work based on the Program is not required to print an announcement These requirements apply to the modified work as a whole If identifiable sections of that work...

Page 19: ...er source or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable If distributio...

Page 20: ...he balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this section to induce you to infringe any patents or oth...

Page 21: ...HE PROGRAM IS LICENSED FREE OF CHARGE THERE IS NO WARRANTY FOR THE PROGRAM TO THE EXTENT PERMITTED BY APPLICABLE LAW EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES...

Page 22: ...r version This program is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU G...

Page 23: ...nterest in the program Gnomovision which makes passes at compilers written by James Hacker signature of Ty Coon 1 April 1989 Ty Coon President of Vice This General Public License does not permit incor...

Page 24: ...r warranty is available during local standard working hours excluding QLogic Observed Holidays 1 13 2 Training QLogic offers certification training for the technical professional for both the SANblade...

Page 25: ...hone 1 952 932 4040 Fax 1 952 932 4018 Europe Middle East and Africa Region Email emeasupport qlogic com Phone Numbers by Language 353 1 6924960 English 353 1 6924961 Fran ais 353 1 6924962 Deutsch 35...

Page 26: ...1 Introduction Technical Support 1 18 59225 00 B S Notes...

Page 27: ...wer Supply and Fan Switch Management Fabrics are managed with the SANsurfer Switch Manager switch management application version 5 00 and the Command Line Interface CLI Refer to the SANbox 1400 Series...

Page 28: ...reset the switch or to place the switch in maintenance mode Maintenance mode sets the IP address to 10 0 0 1 and provides access to the switch for maintenance purposes when flash memory or the reside...

Page 29: ...mentarily press and release the Maintenance button to reset the switch 2 1 2 Chassis LEDs The chassis LEDs shown in Figure 2 3 provide status information about switch operation Refer to Port LEDs on p...

Page 30: ...s and over temperature conditions The Heartbeat LED shows a blink code for POST errors and the over temperature condition Refer to Heartbeat LED Blink Patterns on page 5 3 for more information about H...

Page 31: ...ins illuminated as long as the port is initialized or logged in If the port connection is broken or an error occurs that disables the port the Logged In LED will flash Refer to Logged In LED Indicatio...

Page 32: ...Port fabric ports F_Port FL_Port and expansion ports E_Port Switches come from the factory with all Fibre Channel ports configured as GL_Ports Generic fabric and expansion ports function as follows A...

Page 33: ...h over an Ethernet connection using SANsurfer Switch Manager the Command Line Interface CLI or SNMP The switch through which the fabric is managed is called the fabric management switch The Ethernet p...

Page 34: ...oes not monitor or report fan operational status Air flow is front to back To energize the switch do the following 1 Plug the external power supply DC plug into the DC receptacle on the back of the sw...

Page 35: ...ric through the Ethernet port of one or more switches and can provide in band management for all other switches in the fabric Refer to the SANbox 1400 Series Switch Management User s Guide for informa...

Page 36: ...stributor or authorized reseller for information about the SANsurfer Switch Manager API 2 5 5 Simple Network Management Protocol SNMP provides monitoring and trap functions for the fabric SANbox firmw...

Page 37: ...needed The switch uses SFP transceivers but the device host bus adapters you are using may not Consider whether the device adapters use SFP or Gigabit Interface Converters GBIC transceivers and choos...

Page 38: ...e defined for a fabric but only one zone set can be active at one time The active zone set determines the current fabric zoning A zoning database is maintained on each switch consisting of all inactiv...

Page 39: ...and F_Ports 3 2 2 Access Control List Hard Zones Access Control List ACL zoning divides the fabric for purposes of controlling discovery and inbound traffic ACL zoning is a type of hard zoning that is...

Page 40: ...maximum sized frames For fibre optic cables this enables full bandwidth over the following approximate distances 13 kilometers at 1 Gbps 0 6 credits Km 6 kilometers at 2 Gbps 1 2 credits Km 3 kilomet...

Page 41: ...bined destination bandwidth is greater than or equal to the source bandwidth In multiple chassis fabrics each link between chassis contributes 103 206 or 412 megabytes of bandwidth between those chass...

Page 42: ...equirements of your application Storage applications such as video distribution medical record storage retrieval or real time data acquisition can have specific latency or bandwidth requirements The S...

Page 43: ...User s Guide for information about changing the domain ID and domain ID lock using SANsurfer Switch Manager Refer to the Set Config Command on page B 40 for information about changing the default doma...

Page 44: ...ty to manage switches across inter switch links using SANsurfer Switch Manager SNMP management server or the application programming interface The switch comes from the factory with inband management...

Page 45: ...t is resident on the switch Consider how many fabrics will be managed how many management workstations are needed and whether the fabrics will be managed with the CLI SANsurfer Switch Manager or the S...

Page 46: ...3 Planning Fabric Management 3 10 59225 00 B S Notes...

Page 47: ...agement workstations running SANsurfer Switch Manager are described in Table 4 1 Telnet workstations require an RJ 45 Ethernet port and an operating system with a Telnet client Table 4 1 Management Wo...

Page 48: ...and accessories The SANbox 1400 Series product is shipped with the following components SANbox 1400 Series Fibre Channel Switch 1 with firmware installed Power supply 1 Power cord 1 Rubber feet 4 CD R...

Page 49: ...r des blessures ou d endommager l quipement WARNUNG Switches so in das Rack einbauen dass das Gewicht gleichm ig verteilt ist Ein Rack mit ungleichm iger Gewichtsverteilung kann schwanken umfallen und...

Page 50: ...snaps in place To remove a transceiver gently press the transceiver into the port to release the tension then pull on the release tab or lever and remove the transceiver Different transceiver manufac...

Page 51: ...rect Ethernet connection from the management workstation to the switch RJ 45 Ethernet connector through an Ethernet switch or a hub This requires a 10 100 Base T straight cable as shown in Figure 4 1...

Page 52: ...your workstation For a Windows workstation do the following 1 Choose the Start button Choose Settings Control Panel Network and Dial Up Connections 2 Choose Make New Connection 3 Click the Connect to...

Page 53: ...Series Switch Management User s Guide for more information about using exiting and uninstalling SANsurfer Management Suite and SANsurfer Switch Manager 4 2 5 1 SANsurfer Switch Manager You can instal...

Page 54: ...ll program and follow the installation instructions Linux_5 00 xx bin For a Solaris platform 1 Open a terminal window If the disk isn t already mounted enter the following command volcheck 2 Move to t...

Page 55: ...click the drive letter which contains the SANsurfer Management Suite Disk b Locate and double click the Start_Here htm file to open the SANsurfer Management Suite start page in your default browser 2...

Page 56: ...step 9 Otherwise no upgrade is needed and the SMS installation is complete 9 To start the installer open the zip file and run the SANsurferSwitchMgr_Windows_x xx xx exe file 10 When prompted for an in...

Page 57: ...wser to view the Start_Here htm document using one of the following commands mozilla file mnt cdrom Start_Here htm or netscape file mnt cdrom Start_Here htm d The SANsurfer Management Suite start page...

Page 58: ...5 00 xx is greater than what is currently installed on your workstation down load the new version and proceed to step 11 Otherwise no upgrade is needed and the SMS installation is complete 11 From the...

Page 59: ...ment Suite start page click the SANbox Switch Software button 3 On the SANbox Switch Software page scroll to the SANbox Series area 4 In the Operating System column click the Solaris SPARC link 5 Clic...

Page 60: ...hMgr_QLGCsol_x xx xx bin file in a folder and make the file executable chmod x sansurferswitchmgr_QLGCsol_x xx xx 12 Install the new SANsurfer Switch Manager package pkgadd d sansurferswitchmgr_QLGCso...

Page 61: ...itch and lead you through the configuration process To start SANsurfer Switch Manager from SANsurfer Management Suite do the following 3 Start the SANsurfer Management Suite application using one of t...

Page 62: ...e must be rated at 10 Amps and be approved by UL and CSA For 250 Volt electrical service The cable must be rated at 10 Amps meet the requirements of H05VV F and be approved by VDE SEMKO and DEMKO AVER...

Page 63: ...er second the POST was successful and you can continue with the installation Any other blink pattern indicates an error Refer to Heartbeat LED Blink Patterns on page 5 3 for more information about err...

Page 64: ...The Configuration wizard explains and prompts you for the configuration information shown in Table 4 2 Table 4 2 Configuration Wizard Parameters Temporary IP address Temporary subnet mask Archive tem...

Page 65: ...Refer to the Config Command on page B 11 and Set Config Command on page B 40 for more information 4 2 9 Cable Devices to the Switch Connect cables to the SFP transceivers and their corresponding devi...

Page 66: ...ch will perform a disruptive activation The current firmware version is a 4 x version that precedes the upgrade version No changes are being made to switches in the fabric including powering up poweri...

Page 67: ...he Start button to begin the firmware load process You will be shown a message warning you that the switch will be reset to activate the firmware 4 Click the OK button to continue firmware installatio...

Page 68: ...agement sessions including any Telnet sessions When the firmware activation is complete you may log in to the switch again Do you want to continue y n y Press q and the ENTER key to abort this command...

Page 69: ...Input Power LED and System Fault LED indications Power On Self Test Diagnostics describe the Heartbeat LED and the port Logged In LED indications This section also describes how to use maintenance mo...

Page 70: ...source Is the power source delivering the proper voltage Yes Replace the switch power supply cord If the condition remains contact your authorized maintenance provider No Make necessary repairs If th...

Page 71: ...f a critical error occurs the Heartbeat LED will show an error blink pattern and the System Fault LED will illuminate If there are non critical errors the switch disables the failed ports and flashes...

Page 72: ...ks followed by a two second pause The 3 blink error pattern indicates that a POST failure or a system error has left the switch inoperable If a system error occurs contact your authorized maintenance...

Page 73: ...key to recreate the configuration file 0 Exit 1 Image Unpack 2 Reset Network Config 3 Reset User Accounts to Default 4 Copy Log Files 5 Remove Switch Config 6 Remake Filesystem 7 Reset Switch 8 Update...

Page 74: ...nter one of the following on the command line telnet xxx xxx xxx xxx or telnet switchname where xxx xxx xxx xxx is the switch IP address and switchname is the switch name associated with the IP addres...

Page 75: ...0 C If the Heartbeat LED shows the over temperature blink pattern do the following 1 Inspect the chassis vents Are the intake and exhaust vents clear Yes Continue No Remove any debris from fan intake...

Page 76: ...n also inspect the alarm log using the Show Alarm command If there is an error alarm messages may point to one or more of the following conditions E_Port Isolation Excessive Port Errors 5 2 2 1 E_Port...

Page 77: ...timeout values for all switches in the fabric using the Show Config Switch command or the Switch data tab of the SANsurfer Switch Manager topology display Is each timeout value the same on every switc...

Page 78: ...rm and disables the affected port changing its operational state to down Port errors can be caused by the following Triggers are too low or the sample window is too small Faulty Fibre Channel port cab...

Page 79: ...ly Make repairs and corrections as needed If the condition remains contact your authorized maintenance provider 5 3 Recovering a Switch A switch can become inoperable or unmanageable for the following...

Page 80: ...ntenance menu displays several recovery options To select a switch recovery option press the corresponding number displayed in option field on the keyboard and press the Enter key 0 Exit 1 Image Unpac...

Page 81: ...net session with the switch using the default IP address 10 0 0 1 telnet 10 0 0 1 4 Enter the maintenance mode account name and password prom prom and press the Enter key Switch login prom Password xx...

Page 82: ...ion is stored must be re created This option resets the switch to the factory default values including user accounts and zoning Refer to Table B 3 though Table B 8 for the factory default values 5 3 8...

Page 83: ...Protocols FC PH Rev 4 3 FC PH 2 FC PH 3 FC AL Rev 4 6 FC AL 2 Rev 7 0 FC FLA FC GS FC GS 2 FC GS 3 FC FG FC Tape FC VI FC SW 2 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 4 0 Fibre C...

Page 84: ...ze 2148 bytes 2112 byte payload System Processor Integrated IBM PowerPC PPC405 core Fabric Latency intra switch 1 Gbps to 1 Gbps 2 Gbps to 2 Gbps 4 Gbps to 4 Gbps 0 6 sec 0 4 sec 0 2 sec Bandwidth Poi...

Page 85: ...tch Agent Allows a network management station to obtain configuration values traffic information and failure data pertaining to the Fibre Channels using SNMP through the Ethernet interface Width Heigh...

Page 86: ...g 15 to 80 non condensing 25 to 90 non condensing Altitude Operating Non operating 0 to 3048m 0 to 10 000 feet 0 to 15 240m 0 to 50 000 feet Vibration Operating Non operating IEC 68 2 5 500 Hz random...

Page 87: ...nada EN60950 2000 EC CB Scheme IEC 60950 1999 Emissions Standards FCC Part 15B Class A ICES 03 Issue 3 VCCI Class A ITE CISPR 22 Class A EN 55022 Class A Voltage Fluctuations EN 61000 3 3 Harmonics EN...

Page 88: ...A Specifications Regulatory Certifications A 6 59225 00 B S Notes...

Page 89: ...section describes the following Logging On to a Switch User Accounts Working with Switch Configurations Commands B 1 Logging On to a Switch To log on to a switch using Telnet open a command line wind...

Page 90: ...Refer to Passwd Command on page B 27 for information about changing passwords B 3 Working with Switch Configurations Successful management of switches and fabrics with the command line interface depen...

Page 91: ...t list of configurations default config_10132003 To modify a switch configuration you must open an Admin session with the Admin Start command An Admin session prevents other accounts from making chang...

Page 92: ...3 2 Backing up and Restoring Switch Configurations Backing up and restoring a configuration is useful to protect your work or for use as a template in configuring other switches The Config Backup com...

Page 93: ...and the Config Restore command To upload the configuration file config_switch_169_10112003 in this case open and FTP session with account name images and password images Transfer the file in binary m...

Page 94: ...Delete keyword can be abbreviated Del The command line completion feature makes entering and repeating commands easier Table B 1 describes the command line completion keystrokes Table B 1 Command Lin...

Page 95: ...ommands Listed by Authority Level Monitoring Commands Configuration Command Help History Ping Ps Quit Show Show Config Show Log Show Perf Show Setup Uptime Whoami B 20 B 21 B 28 B 29 B 30 B 62 B 77 B...

Page 96: ...start or begin Opens the admin session end or stop Closes the admin session The Hardreset Hotreset Logout Shutdown and Reset Switch commands will also end an admin session cancel Terminates an Admin...

Page 97: ...ias can have a maximum of 2000 members A port device in member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can be 1 239 port numbers can...

Page 98: ...This keyword does not require an admin session remove alias member_list Removes the ports devices given by member_list from the alias given by alias Use a space to delimit ports devices in member_list...

Page 99: ...configuration can be active at a time backup Creates a file named configdata which contains the system configuration information To download this file open an FTP session log in with account name pas...

Page 100: ...ame If you omit config_name the value for config_name you chose for the most recent Config Edit command is used config_name can be up to 31 characters excluding semicolon and comma The switch supports...

Page 101: ...igdata from the workstation to the switch and then restore the configuration ftp symbolic_name or ip_address user images password images ftp bin ftp put configdata ftp quit SANbox admin start SANbox a...

Page 102: ...to send it to a remote host This file is useful to technical support personnel for troubleshooting switch problems Use this command when directed by your authorized maintenance provider The command p...

Page 103: ...ersion wu 2 6 1 18 ready 331 Password required for johndoe Password xxxxxxx 230 User johndoe logged in cd bin support 250 CWD command successful lcd itasca conf images Local directory now itasca conf...

Page 104: ...ol NTP must be disabled to set the time with the Date command Refer to the Set Setup Command on page B 57 System keyword for information about NTP Authority Admin session except to display the date Sy...

Page 105: ...ture Command Displays the license key feature log Authority None Syntax feature add license_key log Keywords add license_key This keyword does not apply to this switch because there are no licensable...

Page 106: ...ll command SANbox admin firmware install Warning Installing new firmware requires a switch reset Continuing with this action will terminate all management sessions including any Telnet sessions When t...

Page 107: ...tivates the pending firmware and clears the alarm log To save the alarm log before resetting refer to the Set Log Command on page B 51 Authority Admin session Syntax hardreset Notes To reset the switc...

Page 108: ...mand all Displays a list of all available commands including command variations Examples The following is an example of the Help Config command SANbox help config config CONFIG_OPTIONS The config comm...

Page 109: ...hes command_string Enter line number to re execute the corresponding command from the History display Enter partial command string to re execute a command that matches the command string Enter to re e...

Page 110: ...ng to re initialize attached devices under the following conditions The current firmware version is a 5 0 x version that precedes the upgrade version No changes are being made to switches in the fabri...

Page 111: ...password to access the FTP server the system will prompt you for it install Downloads firmware from a remote host to the switch installs the firmware then resets the switch to activate the firmware Th...

Page 112: ...copy the firmware image file on the switch ftp bin ftp put filename 6 Wait for the transfer to complete then close the FTP session xxxxx bytes sent in xx secs ftp quit 7 Establish communications with...

Page 113: ...th this action will terminate all management sessions including any Telnet sessions When the firmware activation is complete you may log in to the switch again Do you want to continue y n y Press q an...

Page 114: ...and Reinitializes the specified loop port Authority Admin session Syntax lip port_number Keywords port_number The number of the port to be reinitialized Ports are numbered beginning with 0 Examples Th...

Page 115: ...name The user account name To change the password for an account name other than your own you must open an admin session with the account name Admin If you omit account_name you will be prompted to ch...

Page 116: ...eywords ip_address The IP address of the switch to query Examples The following is an example of a successful Ping command SANbox ping 10 20 11 57 Ping command issued Waiting for response SANbox Respo...

Page 117: ...18 35 ds 342 327 0 2 00 11 29 3 01 18 35 mgmtApp 343 327 0 0 00 00 04 3 01 18 35 fc2 344 327 0 0 00 02 16 3 01 18 35 nserver 345 327 0 0 00 02 44 3 01 18 35 mserver 346 327 0 8 00 35 12 3 01 18 35 uti...

Page 118: ...B Command Line Interface Quit Command B 30 59225 00 B S Quit Command Closes the Telnet session Authority None Syntax quit exit or logout Notes You can also enter Control D to close the Telnet session...

Page 119: ...vate the configuration for the changes to take effect Refer to Table B 3 through Table B 6 for switch port and port threshold alarm configuration default values factory Resets switch configuration por...

Page 120: ...page B 22 system Resets the system configuration settings to the factory default values Refer to Table B 8 for system configuration default values zoning Clears the zoning database and deactivates the...

Page 121: ...Default Admin State Online Link Speed Auto Port Type GL Symbolic Name Port n where n is the port number ALFairness False DeviceScanEnabled True ForceOfflineRSCN False ARB_FF False InteropCredit 0 ExtC...

Page 122: ...SampleWindow True 25 1 10 DecodeErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 25 0 10 ISLMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 2 0 10 LoginMonitorin...

Page 123: ...able B 7 SNMP Configuration Defaults Parameter Default SNMPEnabled True Contact syscontact undefined Location sysLocation undefined Description SANbox 1400 FC Switch Trap 1 5 Address Trap 1 10 0 0 254...

Page 124: ...twork Discovery Static Ethernet Network IP Address 10 0 0 1 Ethernet Network IP Mask 255 0 0 0 Ethernet Gateway Address 10 0 0 254 Admin Timeout 30 minutes InactivityTimeout 0 LocalLogEnabled True Rem...

Page 125: ...eam or clears the alarm log option can be one of the following clear Clears the alarm log history This value requires an Admin session on Enables the display of alarms in the session output stream off...

Page 126: ...ing Active List off Allows continuous display of information without a break port option Sets port state and speed for the specified port The previous Set Config Port settings are restored after a swi...

Page 127: ...orkstation The default is Universal Time UTC also known as Greenwich Mean Time GMT This keyword prompts you to choose a region then a subregion to specify the time zone Examples The following examples...

Page 128: ...y to accept the current value shown in brackets Enter q to end the configuration for one port or qq to end the configuration for all ports Table B 9 describes the port parameters ports port_number Ini...

Page 129: ...rrupted If enabled the RSCN message is delayed for 200 ms for locally attached devices and 400 ms for devices connected through other switches The default is False This param eter is ignored if IOStre...

Page 130: ...e Sequence bundling This parameter appears only if AutoPerfTuning is False Prevents True or allows False the interleaving of frames in a sequence The default is False Enabling MFSEnable disables LCFEn...

Page 131: ...SCN mes sages under the following conditions 1 The port is connected to an initiator device with a QLogic HBA 2 The DeviceScanEnable parameter is enabled Auto is the default PDISCPingEnable Enables Tr...

Page 132: ...eout Value The number of millisec onds a port is to wait for errors to clear The default is 2000 PrincipalPriority The priority used in the FC SW 2 principal switch selection algorithm 1 is high 255 i...

Page 133: ...shold Parameters Parameter Description Threshold Monitoring Enabled Master enable disable parameter for all events Enables True or disables False the generation of all enabled event alarms The default...

Page 134: ...ent memory Refer to InteropMode on page B 44 The default is True Disabling the Autosave parameter can be useful to prevent the propagation of zoning information when experimenting with dif ferent zoni...

Page 135: ...s A Auto Auto PortType GL G F FL Donor GL SymPortName string max 32 chars Port1 ALFairness True False False DeviceScanEnable True False True ForceOfflineRSCN True False False ARB_FF True False False I...

Page 136: ...efore reaching the end of the list press q or Q and the ENTER key to do so AdminState 1 Online 2 Offline 3 Diagnostics Online BroadcastEnable True False False InbandEnabled True False False FDMIEnable...

Page 137: ...imal value 1 1000 25 FallingTrigger decimal value 0 1000 0 SampleWindow decimal value 1 1000 sec 10 ISLMonitoringEnabled True False True RisingTrigger decimal value 1 1000 2 FallingTrigger decimal val...

Page 138: ...ue or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so InteropAutoSave True Fals...

Page 139: ...l log entries and stores the result in new file named logfile that is maintained in switch memory where it can be downloaded using FTP To download logfile open an FTP session log in with account name...

Page 140: ...automatically display on the screen according to the event severity levels given by filter filter can be one of the following values Critical Critical severity level events The critical level describe...

Page 141: ...ibes events that are generally not disruptive to the administration or operation of the fabric but are more important than the informative level events Info Monitors informative warning and critical e...

Page 142: ...and start Starts the logging of events based on the Port Component and Level keywords assigned to the current configuration The logging continues until you enter the Set Log Stop command stop Stops lo...

Page 143: ...d beginning with 0 bypass alpa Sends a Loop Port Bypass LPB to a specific Arbitrated Loop Physical Address ALPA or to all ALPAs on the arbitrated loop alpa can be a specific ALPA or the keyword ALL to...

Page 144: ...the port online This activates and prepares the port to send data Offline Places the port offline This prevents the port from receiving signal and accepting a device login Diagnostics Prepares the por...

Page 145: ...events The name can be up to 64 characters excluding semicolon and comma The default is undefined Location Specifies the name of the switch location The name can be up to 64 characters excluding semi...

Page 146: ...te community password can be up to 32 characters excluding semicolon and comma The default is private TrapCommunity Trap community password that authorizes an SNMP agent to receive traps This is a wri...

Page 147: ...lt is False RemoteLogHostAddress The IP address of the host that will receive the switch event log information if remote logging is enabled The default is 10 0 0 254 NTPClientEnabled Enables True or d...

Page 148: ...ee allowed options above warning Trap1Version 1 2 2 Trap1Enabled True False False Trap2Address dot notated IP Address 0 0 0 0 Trap2Port decimal value 162 Trap2Severity see allowed options above warnin...

Page 149: ...d the ENTER key to do so Eth0NetworkDiscovery 1 Static 2 Bootp 3 Dhcp 4 Rarp Static Eth0NetworkAddress dot notated IP Address 10 0 0 1 Eth0NetworkMask dot notated IP Address 255 255 255 0 Eth0GatewayA...

Page 150: ...chassis config option domains donor fabric fdmi port_wwn interface log option lsdb mem count ns option pagebreak perf option port port_number post log setup option steering domain_id support switch ti...

Page 151: ...nfig option Displays switch port and zoning configuration attributes Refer to the Show Config Command on page B 77 domains Displays list of each domain and its worldwide name in the fabric donor Displ...

Page 152: ...rmation for all switches and ports domain_id Displays name server information for the switch given by domain_id domain_id is a switch domain ID port_id Displays name server information for the port gi...

Page 153: ...port ClassXToss Number of times an SOFi3 or SOFn3 frame is tossed from TBUF DecodeError Number of decode errors detected EpConnects Number of times an E_Port connected through ISL negotia tion FBusy...

Page 154: ...ied by FC AL 2 LossOfSync Number of synchronization losses 100 ms detected by this port A loss of synchronization is detected by receipt of an invalid transmission word PrimSeqErrors Primitive sequenc...

Page 155: ...and on page B 87 steering domain_id Displays the routes that data takes to the switch given by domain_id If you omit domain_id the system displays routes for all switches in the fabric TotalTxFrames T...

Page 156: ...ev Settings Domains Donor Fabric Log Log Archive Log Settings Lsdb Mem Ns Perf Port Setup Mfg Setup Snmp Setup System Steering Switch Topology Users Uptime User Accounts Whoami Zoneset Active List Zon...

Page 157: ...rsion build date Firmware image version and build date that is pending This image will become active at the next reset or power cycle ActiveConfiguration Name of the switch configuration that is in us...

Page 158: ...how domains Principal switch is remote 10 00 00 60 69 50 0b 6c Upstream Principal ISL is 1 Domain ID List Domain 97 0x61 WWN 10 00 00 c0 dd 00 71 ed Domain 103 0x67 WWN 10 00 00 60 69 50 0b 6c The fol...

Page 159: ...wareVersion 03 02 13 OperatingSystem SunOS 5 8 MaximumCTPayload 2040 NumberOfPorts 1 Port 21 01 00 e0 8b 27 aa bc SupportedFC4Types FCP SupportedSpeed 2Gb s CurrentSpeed 2Gb s MaximumFrameSize 2048 OS...

Page 160: ...4Type FCP FC4Desc NULL The following is an example of the Show Interface command SANbox show interface eth0 Link encap Ethernet HWaddr 00 C0 DD 00 BD ED inet addr 10 20 68 107 Bcast 10 20 68 255 Mask...

Page 161: ...mbolicName Port8 MaxCredit 8 SyncStatus SyncAcquired MediaSpeeds 1Gb s 2Gb s 4Gb s XmitterEnabled True ALInit 5 LIP_F8_AL_PS 0 ALInitError 0 LIP_F8_F7 0 BadFrames 0 LinkFailures 2 Class2FramesIn 0 Log...

Page 162: ...x 0 2 day month date time year PendingImageVersion build date Vx x x 0 17 day month date time year ActiveConfiguration default AdminState Online AdminModeActive False BeaconOnStatus False OperationalS...

Page 163: ...tID 650100 PortWWN 20 01 00 c0 dd 00 91 11 PortType F Remote Link Information Device 0 NodeWWN 50 80 02 00 00 06 d5 38 PortType NL Description NULL IPAddress 0 0 0 0 Device 1 NodeWWN 20 00 00 20 37 2b...

Page 164: ...Interface SHell CLISH SystemDescription SANbox 1400 FC Switch Eth0NetworkAddress 10 20 116 37 use set setup system to update MACAddress 00 c0 dd 07 02 17 WorldWideName 10 00 00 c0 dd 07 02 17 Chassis...

Page 165: ...ort_number switch threshold zoning Keywords port port_number Displays configuration parameters for the port number given by port_number Ports are numbered beginning with 0 If port_number is omitted al...

Page 166: ...False MFSEnabled True MSEnabled True NoClose False IOStreamGuard Disabled VIEnabled False PDISCPingEnable True The following is an example of the Show Config Switch command SANbox show config switch...

Page 167: ...onitoringEnabled True RisingTrigger 25 FallingTrigger 1 SampleWindow 10 DecodeErrorsMonitoringEnabled True RisingTrigger 25 FallingTrigger 0 SampleWindow 10 ISLMonitoringEnabled True RisingTrigger 2 F...

Page 168: ...ommand B 80 59225 00 B S The following is an example of the Show Config Zoning command SANbox show config zoning Configuration Name default Zoning Configuration Information InteropAutoSave True Defaul...

Page 169: ...of events component display filter level options port settings Keywords number of events Specifies the number of the most recent events to display from the event log number of events must be a positi...

Page 170: ...o the component or severity level filter given by filter filter can be one of the following Info Displays all informative events Warning Displays all warning events Critical Displays all critical even...

Page 171: ...ettings Displays the current filter settings for component severity level port and display level This command is equivalent to executing the following commands separately Show Log Component Show Log L...

Page 172: ...330 day month date time year I Eport Port 0 8 Processing EFP oxid 0x8 331 day month date time year I Eport Port 0 8 Eport State E_A2_IDLE 332 day month date time year I Eport Port 0 8 EFP WWN 0x10000...

Page 173: ...rmance data in bytes second received for all ports Type q and press the Enter key to stop the display outbyte Displays continuous performance data in bytes second transmitted for all ports Type q and...

Page 174: ...136M 58K 136M 68K 1K 70K 8 7K 136M 136M 245 68K 68K 9 58K 0 58K 1K 0 1K The following is an example of the Show Perf Byte command SANbox show perf byte Displaying bytes sec data Press any key to stop...

Page 175: ...tings system Displays the current system settings Examples The following is an example of the Show Setup Mfg command SANbox show setup mfg Manufacturing Information BrandName QLogic Corporation BuildD...

Page 176: ...rt 162 Trap1Severity warning Trap1Version 2 Trap1Enabled False Trap2Address 0 0 0 0 Trap2Port 162 Trap2Severity warning Trap2Version 2 Trap2Enabled False Trap3Address 0 0 0 0 Trap3Port 162 Trap3Severi...

Page 177: ...tup system System Information Eth0NetworkDiscovery Static Eth0NetworkAddress 10 20 11 32 Eth0NetworkMask 255 255 252 0 Eth0GatewayAddress 10 20 8 254 AdminTimeout 30 InactivityTimeout 0 LocalLogEnable...

Page 178: ...tch at convenient points and closes the Telnet session Always power cycle the switch after entering this command Authority Admin session Syntax shutdown Notes Always use this command to perform an ord...

Page 179: ...al Tests the SerDes for all port speeds independent of the capabilities of the transceiver This is the default The port must be in diagnostics mode to perform this test external Tests both the SerDes...

Page 180: ...TestLength parameter is the number of frames sent the FrameSize 256 byte maximum in some cases parameter is the number of bytes in each frame and the DataPattern parameter is the pattern in the payloa...

Page 181: ...ached to the port can handle the test parameters SANbox admin test port x online A list of attributes with formatting and current values will follow Enter a new value or simply press the ENTER key to...

Page 182: ...last reset and reset method A hot reset or non disruptive firmware activation does not reset the elapsed up time reported by this command Authority None Syntax uptime Examples The following is an exa...

Page 183: ...swords must be 4 20 characters Admin authority grants permission to use the Admin command to open an admin session from which all commands can be entered Without Admin authority you are limited to vie...

Page 184: ...owing is an example of the User Add command SANbox admin user add Press q and the ENTER key to abort this command account name 1 15 chars user1 account password 4 20 chars please confirm account passw...

Page 185: ...y The following is an example of the User List command SANbox admin user list User Ethernet Addr Port Logged in Since admin OB session1 10 20 68 108 1031 day month date time year admin OB session2 10...

Page 186: ...Command Displays the account name session number and switch domain ID for the Telnet session Authority None Syntax whoami Examples The following is an example of the Whoami command SANbox whoami User...

Page 187: ...liases and ports devices in member_list A zone can have a maximum of 2000 members member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can...

Page 188: ...ember_list member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can be 1 239 port numbers can be 0 255 6 character hexadecimal device Fibre...

Page 189: ...23bd31 zone_set_1 wwn_221416 zone_set_1 wwn_2215c3 zone_set_1 wwn_0160ed zone_set_1 wwn_c001b0 zone_set_1 wwn_401248 zone_set_1 wwn_02402f zone_set_1 wwn_22412f zone_set_1 The following is an example...

Page 190: ...B Command Line Interface Zone Command B 102 59225 00 B S The following is an example of the Zone Zonesets command SANbox zone zonesets zone1 Current List of ZoneSets for Zone zone1 zone_set_1...

Page 191: ...ew zones zone_set Keywords activate zone_set Activates the zone set given by zone_set This keyword deactivates the active zone set Close the Zoning Edit session before using this keyword active Displa...

Page 192: ...e removed until the zone set has been deactivated rename zone_set_old zone_set_new Renames the zone set given by zone_set_old to the name given by zone_set_new You can rename the active zone set zones...

Page 193: ...B Command Line Interface Zoneset Command 59225 00 B B 105 A The following is an example of the Zoneset Zones command SANbox zoneset zones ssss Current List of Zones for ZoneSet ssss zone1 zone2 zone3...

Page 194: ...r the active zone set including component zones and zone members This keyword does not require an Admin session cancel Closes the current Zoning Edit session Any unsaved changes are lost clear Clears...

Page 195: ...n session list Lists all fabric zoning definitions This keyword does not require an Admin session restore Reverts the changes to the zoning database that have been made during the current Zoning Edit...

Page 196: ...be activated to implement any changes This does not apply if you entered the Zoning Clear command during the Zoning Edit session Examples The following is an example of the Zoning Edit command SANbox...

Page 197: ...256 6 MaxZones 2000 17 MaxAliases 2500 1 MaxTotalMembers 10000 166 MaxZonesInZoneSets 2000 19 MaxMembersPerZone 2000 10 D_1_JBOD_1 23 D_1_Photons 9 D_2_JBOD1 16 D_2_NewJBOD_2 5 E1JBOD1 5 E2JBOD2 3 Li...

Page 198: ...4 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 23 bd 31 wwn_221416 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 14 16 wwn_2215c3 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2...

Page 199: ...B Command Line Interface Zoning Command 59225 00 B B 111 A 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 14 16 wwn_2215c3 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 15 16...

Page 200: ...B Command Line Interface Zoning Command B 112 59225 00 B S Notes...

Page 201: ...gured Alias A named set of ports or devices An alias is not a zone and can not have a zone or another alias as a member AL_PA Arbitrated Loop Physical Address Arbitrated Loop A Fibre Channel topology...

Page 202: ...Log of messages describing events that occur in the fabric Expansion Port E_Port that connects to another FC SW 2 compliant switch Fabric Database The set of fabrics that have been opened during a SA...

Page 203: ...nection between two switches using E_Ports IP Internet Protocol LIP Loop Initialization Primitive sequence Logged In LED A port LED that indicates device login or loop initialization status Maintenanc...

Page 204: ...transceiver device smaller than a GigaBit Interface Converter that plugs into the Fibre Channel port SNMP Simple Network Management Protocol Soft Zone Soft zoning divides the fabric for purposes of co...

Page 205: ...lation Guide A Zone A set of ports or devices grouped together to control the exchange of information Zone Set A set of zones grouped together The active zone set defines the zoning for a fabric Zonin...

Page 206: ...SANbox 1400 Series Fibre Channel Switch Installation Guide Glossary 6 59225 00 B S Notes...

Page 207: ...alias add members B 9 copy B 9 create B 9 delete B 10 delete members B 10 display list B 10 display members B 10 rename B 10 Alias command B 9 altitude A 4 Arbitrated Loop Physical Address B 55 autho...

Page 208: ...r port 3 4 B 63 E E_Port 2 6 5 8 emissions standards A 5 environmental conditions 4 2 specifications A 4 Ethernet direct connection 4 5 indirect connection 4 5 port 2 7 event logging by component B 51...

Page 209: ...Adapter Heartbeat LED 2 4 5 3 heat output A 3 Help command B 20 History command B 21 host bus adapter 3 1 B 63 Hotreset command B 22 humidity 4 2 A 4 I I O Stream Guard B 43 Image command B 23 immunit...

Page 210: ...test B 91 operating systems 4 1 over temperature 5 7 P page break B 38 Passwd command B 27 password change B 27 factory B 2 file reset 5 13 maintenance mode 5 12 restore default 5 13 switch B 27 perf...

Page 211: ...n 4 7 scalability A 2 security fabric 3 8 fabric services 3 8 user account 3 8 Set command B 37 Set Config command B 40 Set Log command B 51 Set Port command B 55 Set Setup command B 57 SFP See Small...

Page 212: ...B 94 user account 3 8 B 2 interface A 2 logged in B 69 User command B 95 V vibration A 4 Virtual Interface preference routing B 42 voltage fluctuations A 5 operating A 3 W web applet description 2 9 e...

Page 213: ...2 B 104 delete B 104 delete member zone B 104 display B 104 display active B 103 display members B 104 display zones B 100 rename B 104 zone set definition 3 2 Zoneset command B 103 zoning configurati...

Page 214: ...SANbox 1400 Series Fibre Channel Switch Installation Guide Index 8 59225 00 B S Notes...