Parameter
Name
Type
Range
Default
<source>
Discrete
{CH1|CH2|CH3}
-
<value>
Real
0 to 1000 ms
10 ms
<lim>
Discrete
{MINimum|MAXimum}
-
Remarks
•
If <source> is omitted, the command executes the corresponding operation on
the current channel.
•
You can select “MINimum” to set the minimum OCP delay or “MAXimum”
to set the maximum OCP delay.
Return Format
The query returns the OCP delay, for example, 200ms.
Examples
:OUTPut:OCP:DELay CH1 200 /*Sets the OCP delay to 200 ms for CH1.*/
:OUTPut:OCP:DELay? CH1 /*Queries the OCP delay for CH1. The query
returns 200ms.*/
4.8.7
:OUTPut:OCP[:STATe]
Syntax
:OUTPut:OCP[:STATe]
[<
source>,]<bool>
:OUTPut:OCP[:STATe]?
[<
source>]
Description
Sets or queries the on/off state of the overcurrent protection (OCP) function for the
specified channel.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CH1|CH2|CH3}
-
<bool>
Bool
{0|1|ON|OFF}
0
Remarks
•
When OCP is enabled, the output is disabled automatically if the output current
reaches the OCP level (
) currently set. You can
Command System
50
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Summary of Contents for DP900 Series
Page 1: ......
Page 133: ...d Exit Programming Examples Copyright RIGOL TECHNOLOGIES CO LTD All rights reserved 125 ...
Page 141: ......