Remarks
When the template currently selected is ExpRise (
parameters set cannot reach the maximum due to the characteristic of the
exponential function itself. The range of the parameters created is related to the rise
index currently set. The larger the rise index is, the wider the range of the parameters
will be.
Return Format
The query returns an integer between 0 and 10, for example, 5.
Examples
:TIME:TEMP:RISER 5 /*Sets the rise index of ExpRise to 5.*/
:TIME:TEMP:RISER? /*Queries the rise index of ExpRise currently
set. The query returns 5.*/
4.12.20 :TIMEr:TEMPlet:SELect
Syntax
:TIMEr:TEMPlet:SELect
<
temp>
:TIMEr:TEMPlet:SELect?
Description
Sets or queries template type.
Parameter
Name
Type
Range
Default
<temp>
Discrete
{SINE|PULSE|RAMP|UP|DN|
UPDN|RISE|FALL}
SINE
Remarks
None.
Return Format
The query returns SINE, PULSE, RAMP, UP, DN, UPDN, RISE, or FALL.
Examples
:TIME:TEMP:SEL UP /*Selects the Stair Up template.*/
:TIME:TEMP:SEL? /*Queries the template currently selected. The
query returns UP.*/