PLC-XTC50AL Expand Serial Command Functional Specifications
31/76
8.7.4 CF_REAR Command
Command “CF_REAR_%1” [CR]
%1
“ON” --------------------------- Set Rear to ON.
“OFF” ------------------------- Set Rear to OFF.
Details
Set/Cancel Rear mode (Available only in the normal Power ON status)
When Rear is ON, projected image is left/right reversed.
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.7.5 CF_KEYSTONE Command
Command
“CF_KEYSTONE_%1”[CR]
%1
“UP” ------------- Correct Keystone distortion to reduce upper part of image
“FUP” ----------- Correct Keystone distortion to reduce upper part largely
“DN” ------------- Correct Keystone distortion to reduce lower part of image
“FDN” ----------- Correct Keystone distortion to reduce lower part largely
“LEFT” ---------- Correct Keystone distortion to reduce left part of image
“FLFT” ---------- Correct Keystone distortion to reduce left part largely
“RIGHT” -------- Correct Keystone distortion to reduce right part of image
“FRGT” --------- Correct Keystone distortion to reduce right part largely
“RST” ------------ Set Keystone Default
Details
Change Keystone distortion correction
(Available only in the normal Power ON status)
When reached the limit of the correction level, projector accepts the command but
does not execute it. Receiving this command immediately invokes the operation.
When trying to set the value beyond available range, error code “201” is returned
and the operation is not executed.
Example 1: When the correction level of the upper part has reached its upper limit
and then the command “UP” is received.
Example 2: When the upper part correction allows only another step, and then the
command “FUP” is received.
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]
8.7.6 CF_KYSTNMODE Command
Command
“CF_KYSTNMODE_%1”[CR]
%1
“STR” --------- Set Keystone store mode to Store
“RST” --------- Set Keystone store mode to Reset
Details
Set Keystone store mode (Available only in the normal Power ON status)
Response
Acceptable
“000”[CR]
Unacceptable
“Error Code”[CR]