PLC-XTC50AL Expand Serial Command Functional Specifications
67/76
9.11 Setting Status Read Command
9.11.1 CR_LANG Command
Command
“CR_LANG” [CR]
Details
Get selected language
Response
Acceptable
“000_%1” [CR]
%1
“ENG” -------------------------- English is selected
“DEU” -------------------------- German is selected
“FRA” -------------------------- French is selected
“ITA” --------------------------- Italian is selected
“ESP” -------------------------- Spanish is selected
“POR” -------------------------- Portuguese is selected
“NED” -------------------------- Dutch is selected
“SVE” -------------------------- Swedish is selected
“JPN” -------------------------- Japanese is selected
“CHI” -------------------------- Chinese is selected
“KOR” -------------------------- Korean is selected
“RUS” -------------------------- Russian is selected
Unacceptable
“?” [CR]
9.11.2 CR_LOGO Command
Command
“CR_LOGO” [CR]
Details
Get setting status of Logo
Response
Acceptable
“000_%1” [CR]
%1
“DFLT” ----------------------------- Default Logo is enabled
“USER” --------------------------- User is enabled
“OFF” ------------------------------ Logo is disabled
Unacceptable “?” [CR]
9.11.3 CR_LOGOLOCK Command
Command
“CR_LOGOLOCK” [CR]
Details
Get setting status of Logo Lock function
Response
Acceptable
“000_%1” [CR]
%1
“ON” --------------------------- Logo Lock is ON
“OFF” ------------------------- Logo Lock is OFF
Unacceptable “Error Code” [CR]
9.11.4 CR_BACKGND Command
Command
“CR_BACKGND” [CR]
Details
Get setting status of Screen for no signal
Response
Acceptable
“000_%1” [CR]
%1
“BLUE” -------------------------------- Blue Back is selected
“USER” ------------------------------- User is selected
“BLACK” ------------------------------ Black Back is selected
Unacceptable “Error Code” [CR]