PLC-XTC50AL Expand Serial Command Functional Specifications
65/76
9.9.8 CR_LAMPCONTRL Command
Command
“CR_LAMPCONTRL” [CR]
Details
Get setting status of Lamp mode
(Available only in the normal Power ON status)
Response
Acceptable
“000_%1” [CR]
%1
“LAMP1” ------------------ Lamp mode is Lamp1
“LAMP2” ------------------ Lamp mode is Lamp2
“CHANGE” --------------- Lamp control is Lamp1/2
Unacceptable “Error Code” [CR]
9.9.9 CR_LAMPLIFECONTRL
Command
“CR_LAMPLIFECONTRL” [CR]
Details
Get setting status of Lamp life control
(Available only in the normal Power ON status)
Response
Acceptable
“000_%1” [CR]
%1
“MODE1” ------------------ Lamp life control is Mode1
“MODE2” ------------------ Lamp life control is Mode2
Unacceptable “Error Code” [CR]
9.9.10 CR_LAMPCHGTIM Command
Command
“CR_LAMPCHGTIM” [CR]
Details
Get setting status of Timer for Lamp1/2 of Lamp mode
Response
Acceptable
“000_%1” [CR]
%1
“ON” --------------------------- ON is selected
“OFF” ------------------------- OFF is selected
Unacceptable “Error Code” [CR]
9.9.11 CR_LAMPCHGSTA Command
Command
“CR_LAMPCHGSTA” [CR]
Details
Get setting status of Timer Start for Lamp1/2 of Lamp mode
Response
Acceptable
“000_%1” [CR]
%1
“00”-“24” --------------------------- 0-24 hours
Unacceptable “Error Code” [CR]
9.9.12 CR_LAMPINTERVAL Command
Command
“CR_LAMPINTERVAL” [CR]
Details
Get setting status of Lamp interval
Response
Acceptable
“000_%1” [CR]
%1
“01”-“24” ---------------- Start time of Interval is selected
Unacceptable “Error Code” [CR]