5.6.2 %EVNT
– Event Log Get
Description
Get the most recent Event Log information for the specified class and subclass. Trace
log information can also be obtained via S registers.
Syntax
%EVNT=<class>,<subclass>
Parameters
<class>
Event log class (Table 17)
<subclass>
Event log subclass (Table 17)
Information Response Syntax
%EVNT: <dataCount>,<signedBitmask>,<NetworkID>,
<timestamp>,<class>,<subclass>,<priority>,<data0>,
<data1>,…,<dataN>
Parameters
<dataCount>
Number of event data values (corresponding to specified event
class/subclasses)
<signedBitmask>
0 Unsigned
1 Signed
Bit 0 corresponds to <data0>, bit N corresponds to <dataN>
<NetworkID>
First eight characters of the modem's Mobile ID
<timestamp>
Bits [00…07] – Seconds (0…59)
Bits [08…15] – Minute (0…59)
Bits [16…22] – Hour (0…23)
Bits [23…31] – Reserved
<class>
Refer to Table 17
<subclass>
Refer to Table 17
<priority>
1 Critical
2 Major
3 Minor
4 Information