Software Programming
L.
Code Summary (for models ETP-400KSE and ETP-402KSE see page 17)
Command Function
6
Turn on Auxiliary Output 1 for 1 second
*3* …[up to 8 digits]*
Master Access Code entry to change Guard Access Code or
Master Access Code
(Default Code is *3*12345678*)
*4* …[up to 8 digits]*
Guard Access Code entry for phone programming
(Default Code is *4**)
*5*
Turns on unit speaker & microphone when you call in to the unit
Effective for that call only
*9*
Elicit phone ID number
*10* …[up to 8 digits]*
Programs and stores a new Master Access Code
*11* …[up to 8 digits]*
Programs and stores a new Guard Access Code
*12* …[six digits]*
Program phone Identification number
*13* …[up to 18 digits]*
Programs the primary number called by Button #1
*14*[1, 2, or 3]*
Configures phone MODE
(1 is default)
*17* …[minutes]*
Sets conversation timer (1 – 4,320 minutes)
(default is 12
minutes)
*18* …[ring cycles]*
Sets number of ring cycles (1 – 9) before phone aborts call and
either redials the primary phone number or switches to the
secondary phone number
(default is 9 ring cycles)
*19*
Makes call progress tones audible
(default)
[Mode 1]
*20*
Makes call progress tones silent [Mode 1]
*21*
Configures phone for use with a Rolm PBX or a Mitel PBX
*22*
Cancels *21* command
(default)
*23* …[up to 18 digits]*
Programs the secondary number called by Button #1
*24* …[0 – 6]*
Sets "ON" time for Auxiliary Output #1 (incoming calls only)
*25*
Turn ON Auxiliary Output #1, effective for that call only
*26*
Turn OFF Auxiliary Output #1, effective for that call only
*27* …[0 – 6]*
Sets "ON" time for Auxiliary Output #2 (incoming calls only)
*28*
Turn ON Auxiliary Output #2, effective for that call only
*29*
Turn OFF Auxiliary Output #2, effective for that call only
*40* …[0 – 10]*
Sets delay before phone dials (0 – 10 seconds)
May be used to wait to obtain PBX dial tone
(default is 2
seconds)
*49*
Suppress automatic transmission of the phone ID number
(default)
*50*
Automatically transmit phone ID
when guard station answers call
*53*
Sets phone to disconnect if the Guard Station is silent 60 seconds
*54*
Phone will not disconnect if Guard Station is silent
(default)
*55*
Sets phone to disconnect if the Guard Station is silent 30 seconds
*56*
Sets Button #1 to activate Output #2 when pushed
*57*
Cancels *56* command
(default)
*58* Record
your
identification
message
*59*
Playback the recorded identification message
*64*
Make Auxiliary Output #1 drive an additional LED