7.2 Setting up the Bar Code Reading System
Item
Serial Command
Description
Data matrix
SET=dM0
Disable reading of Data matrix
SET=dM1
Read Square Data matrix Label
SET=dM2
Read Square Data matrix Black and White reversal Label
SET=dM3
Read Square Data matrix Normal Label and Black and White reversal Label
Reading performed both Label
SET=dM5
Read Square and Rectangle Data matrix Label
SET=dM6
Read Square and Rectangle Data matrix Black and White reversal Label
SET=dM7
Read Square and Rectangle Data matrix Normal Label, Black and White
reversal Label (Reading performed all of label with Data matrix)
(*)
DIGIT=db,c
Data matrix Reading performed from Min. digit (b) to Max. digits(c)
EDIT=db,c
Data matrix data transmitted specific digits from b digits to c digits
QR Code
SET=QM0
Disable reading QR Code
SET=QM1
Read QR Code Normal Label
SET=QM2
Read QR Code Black and White reversal Label
SET=QM3
QR Code Normal Label and Black and White reversal Label
Reading performed both Label
(*)
DIGIT=Qb,c
QR Code Reading performed from Min. digit (b) to Max. digits(c)
EDIT=Qb,c
QR Code data transmitted specific digits from b digits to c digits
Item
Serial Command
Description
Common Setup
MIRROR=0
Reading performed Normal Label(Not Mirror Image)
(*)
MIRROR=1
Reading performed Mirror Image Label
MIRROR=2
Reading performed Normal Label, then in case of No read occurred, try to
read Mirror Image.
SET=#M0
Disable reading for All symbols
SET=#M1
Reading performed for All symbols
SYMBOLTX=0
Disable Transmitting with Symbology Type Information
(*)
SYMBOLTX=1
Transmitting performed with Symbology Type Information
LABELTX=0
Transmitting with Control code: Pass through
(*)
LABELTX=1
Transmitting with Control code: Output with Hexadecimal