DC Power Supply
【
DC-10-D/DC-20-D/DC-10-DH/DC-20-DH
】
6. SERIAL Communication
-61-
Read
Commands
Transmission data
Response data
Write
Commands
Command
Command
Name
Capacity
Description
Capacity
Description
0x98
READ
MONITOR
7byte
Responds collectively with each value of the
electric power, voltage, current, and condition
(Status).
Electric power response command:
0x92
Voltage response command:
0x93
Current response command:
0x94
Condition response command:
0x90
The same data as the above-mentioned ones are
responded.
Responds with data of seven bytes in total.
Responds with the electric power, voltage, and
current each of two bytes.
Electric power -> Voltage -> Current -> Condition
(Status)
The data are sent from the power supply in the
above order.
0xA0
READ
POWER
LIMIT
2byte
Responds with the limit value of the output electric
power.
The value depends on the P/S configuration.
The setting value is one tenth of the response
value.
0.3kW
~
240.0kW
→
3
~
2400
3
:
0x0003
2400
:
0x0960
0x20
0xA1
READ
VOLTAGE
LIMIT
2byte
Responds with the limit value of the output voltage.
The limit value depends on the specifications.
200V
~
800V
→
200
~
800
200V
~
1000V
→
0
~
1000 (
HV spec.)
200
:
0x00C8
800
:
0x0320
1000
:
0x03E8
0x21
0xA2
READ
CURRENT
LIMIT
2byte
Responds with the limit value of the output current.
The value depends on the P/S configuration.
The setting value is one tenth of the response
value.
2.0A
~
600.0A
→
20
~
6000
20
:
0x0014
6000
:
0x1770
0x22
0xA4
READ
PARAMET
ER
1byte
Set any one of two arc parameter types: A or B.
For ARC MODE that can be queried by 0xA5 to
0xAE shown below, it is the value of A if the SET
value specified in the power supply is set to A,
whereas it is the value of B if the SET value
specified in the power supply is set to B.
SET_A
:
0x00
SET_B
:
0x01
0x24