WMO2 G900 / G1800 / G1900
WCOM/GSM/WMO2/WMO2ATDOC
Friday 21 May 1999
WAVECOM confidential ©
42
4.4.4
Facility lock
+CLCK
This command shall be used by the application to lock, unlock or
interrogate a ME or network facility <fac>.
Command syntax: AT+CLCK= <fac>,<mode>[,<passwd>[,<class>] ]
Response syntax: +CLCK: <status> [ ,<class1> ]
<CR><LF>+CLCK: <status>,<class2>
[ … ] ]
The following
<fac>
values are supported:
"PS": SIM lock facility with a 8 digits password.
"SC": PIN enable (<mode> = 1) / disable (<mode> = 0)
"AO": BAOC (Barr All Outgoing Calls)
"OI": BOIC (Barr Outgoing International Calls)
"OX": BOIC-exHC (Barr Outg. Internat Calls except to Home Country)
"AI": BAIC (Barr All Incoming Calls)
"IR": BIC-Roam (Barr Inc. when Roaming outside Home Country)
"AB": All Barring services
"AG": All outGoing barring services
"AC": All inComing barring services
"PN": Network lock with a 8 digits password (NCK).
“FD”: SIM Fixed Dialling Numbers (FDN) memory feature (PIN2 is
required as <password>)
<mode>
0: unlock the facility
1: lock the facility
2: query status
<class>:
A facility status can be changed for only one class, or for all
classes (7 or omitted).
1: Voice (telephony)
2: Data (refer to all bearer services)
4: Fax (facsimile services)
8: Short Message service
7: equal to all classes (Default value)