KLIC-MITT v2
Technical Support:
36
51, 57
1 Byte
I
C - - W -
DPT_Scaling
0% - 100%
[Ix] [Long Press] Dimming Status (Input)
0% - 100%
1 Byte
I
C - - W -
DPT_Scaling
0% - 100%
[Ix] [Long Press] Shutter Status (Input)
0% = Top; 100% = Bottom
58
1 Byte
I
C - - W -
DPT_SceneNumber
0 - 63
[Motion Detector] Scene Input
Scene Value
59
1 Byte
C T - - -
DPT_SceneControl
0-63; 128-191
[Motion Detector] Scene Output
Scene Value
60, 89
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] Luminosity
0-100%
61, 90
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Open Circuit Error
0 = No Error; 1 = Open Circuit Error
62, 91
1 Bit
O
C T R - -
DPT_Alarm
0/1
[Ix] Short Circuit Error
0 = No Error; 1 = Short Circuit Error
63, 92
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] Presence State (Scaling)
0-100%
64, 93
1 Byte
O
C T R - -
DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building Protection
[Ix] Presence State (HVAC)
Auto, Comfort, Standby, Economy,
Building Protection
65, 94
1 Bit
O
C T R - -
DPT_Occupancy
0/1
[Ix] Presence State (Binary)
Binary Value
1 Bit
O
C T R - -
DPT_Ack
0/1
[Ix] Presence: Slave Output
1 = Motion Detected
66, 95
1 Bit
I
C - - W -
DPT_Window_Door
0/1
[Ix] Presence Trigger
Binary Value to Trigger the Presence
Detection
67, 96
1 Bit
I
C - - W -
DPT_Ack
0/1
[Ix] Presence: Slave Input
0 = Nothing; 1 = Detection from slave
device
68, 97
2 Bytes
I
C - - W -
DPT_TimePeriodSec
0 - 65535
[Ix] Presence: Waiting Time
0-65535 s.
69, 98
2 Bytes
I
C - - W -
DPT_TimePeriodSec
0 - 65535
[Ix] Presence: Listening Time
1-65535 s.
70, 99
1 Bit
I
C - - W -
DPT_Enable
0/1
[Ix] Presence: Enable
According to parameters
71, 100
1 Bit
I
C - - W -
DPT_DayNight
0/1
[Ix] Presence: Day/Night
According to parameters
72, 101
1 Bit
O
C T R - -
DPT_Occupancy
0/1
[Ix] Presence: Occupancy State
0 = Not Occupied; 1 = Occupied
73, 102
1 Bit
I
C - - W -
DPT_Ack
0/1
[Ix] External Motion Detection
0 = Nothing; 1 = Motion detected by an
external sensor
74, 79, 84, 103,
108, 113
1 Byte
O
C T R - -
DPT_Scaling
0% - 100%
[Ix] [Cx] Detection State (Scaling)
0-100%
75, 80, 85, 104,
109, 114
1 Byte
O
C T R - -
DPT_HVACMode
1=Comfort
2=Standby
3=Economy
4=Building Protection
[Ix] [Cx] Detection State (HVAC)
Auto, Comfort, Standby, Economy,
Building Protection
76, 81, 86, 105,
110, 115
1 Bit
O
C T R - -
DPT_Switch
0/1
[Ix] [Cx] Detection State (Binary)
Binary Value
77, 82, 87, 106,
111, 116
1 Bit
I
C - - W -
DPT_Enable
0/1
[Ix] [Cx] Enable Channel
According to parameters
78, 83, 88, 107,
112, 117
1 Bit
I
C - - W -
DPT_Switch
0/1
[Ix] [Cx] Force State
0 = No Detection; 1 = Detection
118 - 149
1 Bit
I
C - - W -
DPT_Bool
0/1
[LF] (1-Bit) Data Entry x
Binary Data Entry (0/1)
150 - 165
1 Byte
I
C - - W -
DPT_Value_1_Ucount
0 - 255
[LF] (1-Byte) Data Entry x
1-Byte Data Entry (0-255)
166 - 181
2 Bytes
I
C - - W -
DPT_Value_2_Ucount
0 - 65535
[LF] (2-Byte) Data Entry x
2-Byte Data Entry
DPT_Value_2_Count
-32768 -32767