                   QUAD Plus 

http://www.zennio.com

 

 

   

                       

Technical Support:

 http://support.zennio.com 

 

13 

0x8 (Stop) 

0x9 (Inc. by 100%) 

… 

0xF (Inc. by 1%)

 

1 Bit

 

 

C T - - -

 

DPT_Switch

 

0/1

 

[Ix] [Long Press] Dimmer ON

 

Sending of 1 (ON)

 

1 Bit

 

 

C T - - -

 

DPT_Switch

 

0/1

 

[Ix] [Long Press] Dimmer OFF

 

Sending of 0 (OFF)

 

1 Bit

 

I

 

C T - W -

 

DPT_Switch

 

0/1

 

[Ix] [Long Press] Dimmer ON/OFF

 

Switching 0/1

 

1 Byte

 

 

C T - - -

 

DPT_SceneControl

 

0-63

 

[Ix] [Long Press] Run Scene

 

Sending of 0 - 63

 

1 Byte

 

 

C T - - -

 

DPT_SceneControl

 

128-191

 

[Ix] [Long Press] Save Scene

 

Sending of 128 - 191

 

1 Bit

 

O

 

C T R - -

 

DPT_Alarm

 

0/1

 

[Ix]  [Switch/Sensor] Alarm: Breakdown or 

sabotage

 

1 = Alarm; 0 = No Alarm

 

2 Bytes

 

 

C T - - -

 

9.xxx

 

-671088.64 - 

670760.96

 

[Ix] [Long Press] Constant Value (float)

 

Float value

 

2 Bytes

 

 

C T - - -

 

DPT_Value_2_Ucount

 

0 - 65535

 

[Ix] [Long Press] Constant Value (Integer)

 

0 - 65535

 

1 Byte

 

 

C T - - -

 

DPT_Scaling

 

0% - 100%

 

[Ix] 

[Long Press] Constant Value 

(Percentage)

 

0% - 100%

 

1 Byte

 

 

C T - - -

 

DPT_Value_1_Ucount

 

0 - 255

 

[Ix] [Long Press] Constant Value (Integer)

 

0 - 255

 

143, 149, 156, 161

 

1 Bit

 

 

C T - - -

 

DPT_Trigger

 

0/1

 

[Ix] [Long Press/Release] Stop Shutter

 

Release -> Stop Shutter

 

144, 150, 157, 162

 

1 Byte

 

I

 

C - - W -

 

DPT_Scaling

 

0% - 100%

 

[Ix] [Long Press] Dimming Status (input)

 

0% - 100%

 

1 Byte

 

I

 

C - - W -

 

DPT_Scaling

 

0% - 100%

 

[Ix] [Long Press] Shutter Status (input)

 

0% = Top; 100% = Bottom

 

163

 

1 Byte

 

I

 

C - - W -

 

DPT_SceneControl

 

0-63

 

[Motion Detector] Scene Input

 

Scene Value

 

164

 

1 Byte

 

 

C T - - -

 

DPT_SceneControl

 

0-63

 

[Motion Detector] Scene Output

 

Scene Value

 

165, 194, 223, 252

 

1 Byte

 

O

 

C T R - -

 

DPT_Scaling

 

0% - 100%

 

[Ix] Luminosity

 

0-100%

 

166, 195, 224, 253

 

1 Bit

 

O

 

C T R - -

 

DPT_Alarm

 

0/1

 

[Ix] Open Circuit Error

 

0 = No Error; 1 = Open Circuit Error

 

167, 196, 225, 254

 

1 Bit

 

O

 

C T R - -

 

DPT_Alarm

 

0/1

 

[Ix] Short Circuit Error

 

0 = No Error; 1 = Short Circuit Error

 

168, 197, 226, 255

 

1 Byte

 

O

 

C T R - -

 

DPT_Scaling

 

0% - 100%

 

[Ix] Presence State (Scaling)

 

0-100%

 

169, 198, 227, 256

 

1 Byte

 

O

 

C T R - -

 

DPT_HVACMode

 

1=Comfort 

2=Standby 

3=Economy 

4=Building 

Protection

 

[Ix] Presence State (HVAC)

 

Auto, Comfort, Standby, Economy, Building 

Protection

 

170, 199, 228, 257

 

1 Bit

 

O

 

C T R - -

 

DPT_Occupancy

 

0/1

 

[Ix] Presence State (Binary)

 

Binary Value

 

1 Bit

 

O

 

C T R - -

 

DPT_Trigger

 

0/1

 

[Ix] Presence: Slave Output

 

1 = Motion Detected

 

171, 200, 229, 258

 

1 Bit

 

I

 

C - - W -

 

DPT_Window_Door

 

0/1

 

[Ix] Presence Trigger

 

Binary Value to Trigger the Presence Detection

 

172, 201, 230, 259

 

1 Bit

 

I

 

C - - W -

 

DPT_Trigger

 

0/1

 

[Ix] Presence: Slave Input

 

0 = Nothing; 1 = Detection from slave device

 

173, 202, 231, 260

 

2 Bytes

 

I

 

C - - W -

 

DPT_TimePeriodSec

 

0-65535

 

[Ix] Presence: Waiting Time

 

0-65535 s.

 

174, 203, 232, 261

 

2 Bytes

 

I

 

C - - W -

 

DPT_TimePeriodSec

 

1-65535

 

[Ix] Presence: Listening Time

 

1-65535 s.

 

175, 204, 233, 262

 

1 Bit

 

I

 

C - - W -

 

DPT_Switch

 

0/1

 

[Ix] Presence: Enable

 

According to parameters

 

176, 205, 234, 263

 

1 Bit

 

I

 

C - - W -

 

DPT_Switch

 

0/1

 

[Ix] Presence: Day/Night

 

According to parameters

 

Summary of Contents for QUAD Plus

Page 1: ...QUAD Plus Analogue Digital Input Module for Motion Sensors Temperature Probes and Binary Inputs ZNIO QUADP USER MANUAL Application program version 1 1 User manual edition 1 1 _a www zennio com...

Page 2: ...com 2 CONTENTS Contents 2 1 Introduction 3 1 1 QUAD Plus 3 1 2 Installation 3 2 Configuration 5 2 1 General 5 ETS Parameterisation 5 2 2 Inputs 6 2 2 1 Binary Input 6 2 2 2 Temperature Probe 6 2 2 3...

Page 3: ...detector Moreover QUAD Plus implements four independent thermostats which can be enabled and configured separately as well as the Heartbeat function or periodical still alive notification 1 2 INSTALL...

Page 4: ...mit in red Slots for the Input Lines 3 slots for the insertion of the optional inputs terminal block 4 Alternatively the stripped cables of the input lines can be directly screwed into the slots Each...

Page 5: ...From this screen it is possible to activate deactivate all the required functionality Figure 2 General Heartbeat Periodical Alive Notification enables the Heartbeat Object to Send 1 one bit object wh...

Page 6: ...se refer to the specific user manual Binary Inputs available in the QUAD Plus product section at the Zennio website http www zennio com 2 2 2 TEMPERATURE PROBE Please refer to the specific user manual...

Page 7: ...ctually being connected to the functionality may differ slightly Therefore please refer specifically to the aforementioned user manual Motion detectors with references ZN1IO DETEC and ZN1IO DETEC N ar...

Page 8: ...up to four thermostat functions with independence of the number of the inputs that have been configured Please refer to the specific Zennio Thermostat user manual available under the QUAD Plus produc...

Page 9: ...70760 00 Tx Effective Temperature Effective Control Temperature 6 36 66 96 1 Byte I C W DPT_HVACMode 1 Comfort 2 Standby 3 Economy 4 Building Protection Tx Special Mode 1 byte HVAC Mode 7 37 67 97 1 B...

Page 10: ...riable Cool PI Control Continuous 26 56 86 116 1 Byte O C T R DPT_Scaling 0 100 Tx Control Variable Heat PI Control Continuous 27 57 87 117 1 Bit O C T R DPT_Switch 0 1 Tx Control Variable Cool PI Con...

Page 11: ...up down 4 Bit C T DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x2 Dec by 50 0x3 Dec by 25 0x4 Dec by 12 0x5 Dec by 6 0x6 Dec by 3 0x7 Dec by 1 0x8 Stop 0x9 Inc by 100 0xA Inc by 50 0xB Inc by 25 0xC I...

Page 12: ...Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Long Press 1 Sending of 1 1 Bit I C T W DPT_Switch 0 1 Ix Long Press 0 1 Switching Switching 0 1 1 Bit C T DPT_UpDown 0 1 Ix Long Press Move Up Shutte...

Page 13: ...ol 0 63 Motion Detector Scene Input Scene Value 164 1 Byte C T DPT_SceneControl 0 63 Motion Detector Scene Output Scene Value 165 194 223 252 1 Byte O C T R DPT_Scaling 0 100 Ix Luminosity 0 100 166 1...

Page 14: ...2 271 1 Byte O C T R DPT_Scaling 0 100 Ix C2 Detection State Scaling 0 100 185 214 243 272 1 Byte O C T R DPT_HVACMode 1 Comfort 2 Standby 3 Economy 4 Building Protection Ix C2 Detection State HVAC Au...

Page 15: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: