P1351ieee.wpd
5-1-7
Table 1-1
CIIL SOFTWARE COMMANDS (continued)
CILL COMMANDS
EXPLANATION
IST <cr><lf>
Instructs AC Power Supply to perform internal self test. The STA
command transmits the message. The AC Power Supply responds with
one of the following:
Pass
<sp><cr><lf>
Fail
F07ACSO(DEV): BIT TEST FAILURE
(-PROM CHECKSUM FAULT
*
-RAM FAULT
-AC SUPPLY HARD FAULT
*
<cr><lf>
STA <cr><lf>
Status. Prepares AC Power Supply for a response transmission. Clears
error condition if one exists. The following response messages and
conditions exclude confidence and internal self test.
RESPONSE:
Status OK
<sp><cr><lf>
Device error messages
F07ACSO(DEV):BIT TEST FAILURE
<description consisting of up to 60 characters><cr><lf>
TMA error messages All begin with:
F07ACSO (MOD): This message is followed by one explanatory
message from the following text:
ILLEGAL NOUN : AC Power Supply does not recognize illegal noun.
ILLEGAL NOUN MODIFIER : AC Power Supply does not recognize
illegal noun modifier.
ILLEGAL OPCODE :
AC Power Supply does not recognize illegal
opcode.
ILLEGAL VALUE: Entered value lies outside upper and lower limits.
NO SETUP: Close command received but setup not programmed.
Example: F07ACS00(MOD): NO SETUP <cr><lf>