6-11
Cisco MWR 1941-DC Mobile Wireless Edge Router Software Configuration Guide
OL-11503-01
Chapter 6 Configuring the MWR 1941-DC in a Cell Site DCN
Configuring Asynchronous/Synchronous Serial Network Modules or WAN Interface Cards
Configuration Example
The following is a sample output from the
show running-config
command:
HDLC, DCE Side
!
interface Serial1/3
ip address 45.45.45.62 255.255.255.0
clockrate 64000
no cdp enable
!
HDLC, DTE Side
!
interface Serial1/0
ip address 44.44.44.62 255.255.255.0
no cdp enable
!
Sync PPP, DCE Side
!
interface Serial1/3
ip address 45.45.45.62 255.255.255.0
encapsulation ppp
clockrate 64000
no cdp enable
!
Sync PPP, DTE Side
!
interface Serial1/0
ip address 44.44.44.62 255.255.255.0
encapsulation ppp
no cdp enable
!
Async PPP (same configuration for either side, must set line speed via line interface)
!
interface Serial1/0
physical-layer async
ip address 44.44.44.62 255.255.255.0
encapsulation ppp
async mode dedicated
!
line 33
speed 57600