23
© 2010 Datacom Systems Inc
Initial Configuration
DURA
stream
™
To view specifically what <variable> has what setting in it, type "cli get <variable>."
For example, you want to know if SNMP is enabled, type "cli get snmp." An output will be displayed
showing what SNMP is set to; in this case, it will be either 0 (disabled) or 1 (enabled).
A description of each <variable> and their <options> follows in the '
<variable> List for CLI
' table.
5.1.3 <variable> List for CLI
DS-1010 <variable> <option> list for CLI get/set command.
<variable>
description
<option>
active_hb_cnt
value stores the active heartbeat signal count, segment will
switch to active switch mode only if it receives
“active_hb_cnt” number for a consecutive heartbeat.
default: 1
1-10
bypass_hb_cnt
value stores the bypass heartbeat signal count, segment
will switch to bypass switch mode only if it loses
“bypass_hb_cnt” heartbeat signal number.
default: 1
1-10
current_ip
current ip address for management port.
dhcp
dhcp client enable/disable, setting option to dhcp will
enable dhcp client on Management Port, setting option to
static will disable dhcp client on Management Port.
default: dhcp active
dns
dns server ip address.
dns2
2
ND
dns server ip address.
domain
domain name for local host.
default: local
setting option value to 1 will enable mail notification
feature.
default: 1
email_from
email from field for email report.
email_password
email account password.
email_security
setting option to 1 will enable email security feature.
default: 1
email_server
smtp server address for email report.
email_subject
email report subject.
email_to
email recipient lists.
email_username
email account user name.
23