P r o g r a m m i n g S e c t i o n s :
5 . 3 B a s i c P r o g r a m m i n g
27
[014] SECOND SYSTEM OPTION CODES
[014]
Option
1
Bell Squawk
ON
Arm / Disarm Bell Squawk Enabled.
The Bell output will sound a single squawk when
armed in any manner, including Auto-arm, and a double squawk upon disarming the sys-
tem. If there are alarms in memory, the bell will emit a series of three squawk pairs to indi-
cate the alarm memory.
NOTE:
If you enable the Bell Squawk on Arming/Disarming, the bell will sound arm/dis-
arm bell squawks for all access codes, regardless of the programming for attribute [7] (see
section 4.1 Access Codes on page 12).
NOTE:
Enable both the
Squawk on Away Arming/Disarming Only
and the
Arm/Dis-
arm Bell Squawk
options to have the panel squawk the bell only when the system is
away armed or disarmed.
OFF
Arm / Disarm Bell Squawk Disabled.
The Bell output will not squawk when the system
is armed or disarmed in any manner.
[014]
Option
2
Bell During Auto-Arm
ON
Bell Squawk During Auto-Arm Enabled.
The Bell output will sound a single squawk
every 10 seconds during the Auto-Arm Pre-alert time. This will inform anyone on the pre-
mises that the system is being armed.
OFF
Bell Squawk During Auto-Arm Disabled.
The Bell output will not be activated during
the Auto-Arm warning time.
[014]
Option
3
Bell Squawk On Exit
ON
Bell Squawk On Exit Delay
. The Bell output will squawk once per second during the Exit
Delay time. The bell will also sound 3 squawks per second for the final 10 seconds.
NOTE:
If the panel is armed using the Stay function key, or by entering [*] [9] [Access
Code], there will be no bell squawks during entry and exit delays, except for the arm/dis-
arm bell squawks.
NOTE:
If the panel is armed using the Stay function key there will be no bell squawks dur-
ing the exit delay except for the arm bell squawk. If the panel is no-entry armed using [
✱
]
[9] [Access Code], there will be no bell squawks during the exit delay, except for the arm/
disarm bell squawks. There is no entry delay (and no bell squawks) when the panel is no-
entry armed..
OFF
No Bell Squawk On Exit Delay
.
NOTE:
This audible option does not apply to Stay and No Entry Arming Modes.
[014]
Option
4
Bell Squawk On Entry
ON
Bell Squawk On Entry Delay
. The Bell output will pulse with the same timing as the
buzzer during the Entry Delay time. The bell will also sound 3 squawks per second for the
final 10 seconds if Option 6 in this section is enabled.
NOTE:
Two different Entry Delays are programmable (Delay 1 and Delay 2 Zone defini-
tions. When the panel is armed it will use the Entry Delay for the first Delay zone violated.
NOTE:
This feature must not be used with two or more partitions.
NOTE:
If the panel is armed using the Stay function key, or by entering [*] [9] [Access
Code], there will be no bell squawks during entry and exit delays, except for the arm/dis-
arm bell squawks.
OFF
No Bell Squawk On Entry Delay
[014]
Option
5
Bell Squawk on Trouble
ON
Bell Squawks on Trouble.
When there is a Trouble condition annunciated on the system
keypads, the Bell will squawk 2 times every 10 seconds (as per the keypad buzzer). The
Bell will be silenced when the keypad beeps are silenced (any key pressed on keypad).
OFF
No Bell Squawks on Trouble.
[014]
Option
6
Audible Exit Beeps
ON
Audible Exit With Urgency.
The keypad will sound a pulsing tone (once per second)
during the Exit Delay. For the last 10 seconds of the Exit Delay, the keypad and bell / siren
(if enabled) will sound a different tone (3 tones per second) to warn that the Exit Delay is
about to expire.
NOTE:
Users can restart the exit delay while it is counting down by pressing the Away key.
The system will not log the user who re-started the exit delay, unless the
Quick Arming
Disabled/Function Keys Require Code
option is turned on (section [015], option [4]).
NOTE:
If the system has been Stay armed, or armed with no entry delay ([*][9]), pressing
the Away key will not start an exit delay.
OFF
Silent Exit Delay
. The keypad will not sound during the Exit Delay.
[014]
Option
7
Exit Delay Termination
ON
Exit Delay Termination Enabled.
The Exit Delay will be terminated once a Delay 1 Zone
for the entry/exit door or area is restored. All audible options associated with the exit
delay will be silenced when the Exit Delay is terminated. Force-Armable Delay 1 type
zones will also terminate the exit delay.
NOTE:
If a Delay type zone is violated then secured during the exit delay, the exit delay
will be terminated and the panel will be armed immediately.
OFF
Exit Delay Termination Disabled.
The Exit Delay timer will continue to count even after
the Delay Zone for the entry/exit door or area is restored. All audible options associated
with the Exit Delay will function until the time programmed for the Exit Delay has elapsed.
[014]
Option
8
Fire Bell Timeout
ON
Fire Bell is Continuous.
The Bell output will sound for all Fire type alarms until an access
code is entered to silence the alarm or disarm the system regardless of the time pro-
grammed for Bell Timeout in Section [005].
OFF
Fire Bell Follows Timeout.
The Bell output will sound for all Fire type alarms for the
duration of Bell timeout or until an access code is entered.
Section
Option
On/Off
Description