P r o g r a m m i n g S e c t i o n s :
5 . 6 C o m m u n i c a t o r P r o g r a m m i n g
45
[380]-[382] COMMUNICATOR OPTION CODES
[380] - FIRST COMMUNICATOR OPTION CODES
Option
Communicator Code
On/Off
Description
1
Communications ON
Communicator
Enabled.
The system’s communicator will be enabled and all events with
reporting codes will be reported to the monitoring station. Refer to the Telephone Num-
ber, Reporting Code and Call Direction Programming Sections.
OFF
Communicator Disabled.
The system’s communicator will be shut off and events will
not be transmitted to the monitoring station. Downloading may still be performed if
enabled.
2
Restore Transmission
ON
Restore Transmissions on Bell-Time-out.
Zone restore reporting codes will not be
transmitted until the zone has been restored and the Bell cut-off time has expired. If the
zone is not restored when the bell cut-off time expires, the restore will be transmitted
when the zone physically restores or when the system is disarmed.
NOTE:
24 Hour zones will not restore until the zone is physically restored.
OFF
Restore Transmissions Follow Zones
. Zone restore reporting codes will be transmitted
when the zone is physically restored. If the zones are still active when the system is dis-
armed, the restore codes will be transmitted when the system is disarmed.
NOTE:
24 Hour zones will not restore until the zone is physically restored.
3
Dialing Method
ON
Pulse Dialing enabled.
The control panel will dial telephone numbers using pulse
(rotary) dialing.
OFF
DTMF Dialing enabled.
The control panel will dial telephone numbers using DTMF (dual
tone multi-frequency) dialing.
4
Switch to Pulse Dialing
ON
Switch to Pulse Dialing after 4 DTMF attempts.
If DTMF dialing is enabled, the control
panel will dial telephone numbers using DTMF dialing for the first 4 attempts. If unsuc-
cessful, the control panel will switch to pulse (rotary) dialing for the remaining attempts.
OFF
DTMF Dial for all Attempts.
If DTMF dialing is enabled, the control panel will dial tele-
phone numbers using DTMF dialing for all dialing attempts.
5
3rd Phone Number Enable
ON
3rd Phone Number Enabled
. The 3rd Phone number will be used for Alternate Dialing
with the 1st Phone Number or as a Backup of the 1st Phone Number (see light 6).
OFF
3rd Phone Number Disabled
. The 3rd Phone number will not be used.
6
3rd Phone Number
ON
Alternate Dialing Enabled (1st & 3rd).
After each dialing attempt, the communicator
switches between the 1st Phone Number and 3rd Phone Number.
OFF
Call 1st Number, Backup to 3rd Number.
If the programmed number of attempts to
communicate to the First Telephone Number fail, The same number of attempts will be
made to communicate to the Third Telephone Number. If all attempts to communicate to
the Third Telephone Number fail, a Failure to Communicate Trouble will be generated.
7
LINKS Dialing
ON
Call LINKS as well as Land-line(s).
The control panel will dial the programmed number
of attempts through the LINKS, followed by the number of programmed attempts over
the land-line regardless of whether the communication over the LINKS was successful.
OFF
LINKS is backup of Land-line(s).
The control panel will dial through the LINKS if the
panel is having difficulty communicating over the phone line. For each failed attempt to
the land line, one attempt will be made to the LINKS1000.
8
Delinquency
ON
Delinquency Follows Zone Activity (Activity Delinquency).
This feature assists in the
monitoring of the elderly and the handicapped. If there is no zone activity on a partition,
the Delinquency Transmission Delay timer in Section [370] will begin counting in hours.
When the counter reaches the programmed time, the panel will communicate the Delin-
quency Code to the central station, if programmed. If there is zone activity present on the
system at any time, the counter will be reset. If this option is used, the Closing Delin-
quency option is not available.
NOTE:
This code will not be transmitted for partitions that are “Away” armed. Activity on
Bypassed zones does not affect this timer. The timer is reset on arming.
OFF
Delinquency Follows Arming (Closing Delinquency).
This reporting code is sent
whenever the programmed number of days for Delinquency has expired without the par-
tition being Armed. The timer for this feature is programmed in Section [370]. The value
programmed in this section determines the number of days the partition counts when not
being armed before sending the Delinquency reporting code to the central station. Once
this code is sent, the timer will not be started again until the partition has been armed.
Each day programmed in the counter represents one day PLUS the time it takes for the
partition to reach midnight. This feature may disabled by programming 000 in Section
[370].