MSD-501/502 Command Guide
33
@GST / @SST
Saturation
Function
Getting
Setting
Format
@GST
@SST, ch_1, saturation_1 (, ch_2,
saturation_2
・・・
)
Return value
@GST, saturation_1, saturation_2,
saturation_3, saturation_4, saturation_5
@SST, ch_1, saturation_1 (, ch_2,
saturation_2
・・・
)
Parameter
saturation_1-5: Saturation
0 to 200 [Default]: 100
ch_1-5: Input channel
0 = All inputs, 1 = IN1 to 5 = IN5
Example
@GST
@GST,100,100,100,100,105
Getting saturations.
IN5: 105%; other inputs: 100%
@SST,5,105
@SST,5,105
Setting IN5 saturation to 105%.
Completed normally.
Remarks
-
@GSU / @SSU
Black level
Function
Getting
Setting
Format
@GSU
@SSU, ch_1, setup_1 (, ch_2,
setup_2
・・・
)
Return value
@GSU, setup_1, setup_2, setup_3,
setup_4, setup_5
@SSU, ch_1, setup_1 (, ch_2,
setup_2
・・・
)
Parameter
setup_1-5: Black level
-20 = -20 x 0.5 (-10.0%) to +20 = +20 x 0.5 (+10.0%)
[Default]:
±
0 =
±
0.0%
ch_1-5: Input channel
0 = All inputs, 1 = IN1 to 5 = IN5
Example
@GSU
@GSU,0,0,0,0,15
Getting black levels.
IN5: +7.5%; other inputs: 0%.
@SSU,5,15
@SSU,5,15
Setting IN5 black level to +7.5%.
Completed normally.
Remarks
-