MSD-501/502 Command Guide
38
@GID / @SID
Automatic detection of input video interruption
Function
Getting
Setting
Format
@GID
@SID, ch_1, detect_1 (, ch_2, detect_2
・・・
)
Return value
@GID, detect_1, detect_2, detect_3,
detect_4, detect_5
@SID, ch_1, detect_1 (, ch_2, detect_2
・・・
)
Parameter
detect_1-5: Automatic detection
0 = OFF, 1 = ON [Default]
ch_1-5: Input channel
0 = All inputs, 1 = IN1 to 5 = IN5
Example
@GID
@GID,1,0,1,1,1
Getting the setting of automatic detection of
input video interruption.
IN2: If input video signals are interrupted, the
video output is not turned off instantly;
other inputs: OFF
@SID,2,0
@SID,2,0
If input video signals of IN2 are interrupted, not
to turn off the video output instantly.
Completed normally.
Remarks
-
@GAU / @SAU
Priority of input channel automatic switching
Function
Getting
Setting
Format
@GAU
@SAU, in_1, out_1, priority_1 (, in_2,
out_1, priority_1
・・・
)
Return value
@GAU, in1_out1, in2_out1, in3_out1,
in4_out1, in5_out1, in1_out2, in2_out2,
in3_out2, in4_out2, in5_out2
@SAU, in_1, out_1, priority_1 (, in_2,
out_1, priority_1
・・・
)
Parameter
in1_out1-in5_out2: Priority
0 = OFF, 1 = Priority (high) to 5 = priority (low)
in_1-5: Input channel
1 = IN1 to 5 = IN5
out_1-2: Output channel
0 = All outputs, 1 = OUT1, 2 = OUT2
priority_1-5: Priority
0 = OFF, 1 = Priority (high) to 5 = priority (low)
Example
@GAU
@GAU,1,2,3,4,5,0,4,3,2,1
Getting priority of automatic switching.
OUT1: IN1>IN2>
・・・
>IN5
OUT2: IN1:OFF IN2<IN3
・・・
<IN5
@SAU,1,1,2
@SAU,1,1,2
Setting priority of OUT1 IN1 to “2”.
Completed normally.
Remarks
-