54
Flare 12M CXP User's Manual
3.12.2 Focus
Several registers are used to control lens focus. Table 17 lists the registers and their function.
Register
Function
Lens Control Focus
Minimum
Write 0x1 to set the lens focus to its minimum.
Lens Control Focus Infinity Write 0x1 to set the lens focus to infinity.
Lens Control Focus Step
Size
Step size for Focus Step commands. Range 0x14 to 0xC8.
Effect of step size depends on lens.
Lens Control Focus Step to
Minimum
Write 0x1 to step the lens focus towards its minimum.
Lens Control Focus Step to
Infinity
Write 0x1 to step the lens focus towards infinity.
Table 17. Lens focus control registers
3.12.3 Reset
The lens controller can be reset by writing 0x1 to the
Lens Control Reset
register
3.13 Command Memory
The Flare CXP cameras use non-volatile memory to store up to 8 user command sets. To
save the current camera settings to one of these user sets, first set the
User Set Selector
register to one of the user profiles, 1 to 8, and write a one to the
User Set Save
register. To
load from one of the user sets first set the
User Set Selector
register followed by a write of
one to the
User Set Load
register.
For convenience, and to easily remember what settings are programmed in a user set, the
Flare CXP cameras store a unique 32 byte name for each user set. The eight profile names
are stored in non-volatile memory and can be read or written using the
User Profile X Name
registers starting at address 0x50000000.
Also stored in the camera (in FPGA block ram) is a factory set of commands. To load the
factory profile set the
User Set Selector
register to zero and write a one to the
User Set Load
register. The factory set of commands is full resolution, normal free-run exposure in single
link CXP-3 10-bit output format.
IO Industries Inc.
www.ioindustries.com
Revision 2.0