16
Flare 12M CXP User's Manual
Address
Name / Description
Group
Access Length
(bytes)
Description
0x0000300C
AcquisitionStartAddress
CXP
R
4
0x10000000
0x00003010
AcquisitionStopAddress
CXP
R
4
0x10000004
0x00003014
PixelFormatAddress
CXP
R
4
0x40000000
0x00003018
DeviceTapGeometryAddress
CXP
R
4
0x20000000
0x0000301C
Image1StreamIDAddress
CXP
R
4
0x00007000
0x00003020
Image2StreamIDAddress
CXP
R
4
0x00007004
0x00004000
ConnectionReset
CXP
W
4
Write 0x00000001 to reset
connection
0x00004004
DeviceConnectionID
CXP
R
4
Returns 0x00000000 on
Master Link, and
0x00000001, 0x00000002, or
0x00000003 on respective
Extension Link
0x00004008
MasterHostConnectionID
CXP
R/W
4
Returns 0x00000000 after
connection reset, or last
written value on Master Link
since power up
0x0000400C
ControlPacketSizeMax
CXP
R
4
Max control packet size is
1024 bytes. Returns
0x00000400
0x00004010
StreamPacketSizeMax
CXP
R/W
4
Write any value, max packet
size used is 1744 bytes
0x00004014
ConnectionConfig
CXP
R/W
4
Only 3.125Gbps and
6.25Gbps supported and up
to four links. Write this
register to change the
number of links:
3G 1 link – 0x00010038
3G 2 links – 0x00020038
3G 4 links – 0x00040038
6G 1 link – 0x00010048
6G 2 links – 0x00020048
6G 4 links – 0x00040048
0x00004018
ConnectionConfigDefault
CXP
R
4
Reflects ConnectionConfig
register
0x0000401C
TestMode
CXP
R/W
4
Not implemented
0x00004020
TestErrorCountSelector
CXP
R/W
4
-
0x00004024
TestErrorCount
CXP
R/W
4
-
0x00004028
TestPacketCountTx
CXP
R/W
8
-
0x00004030
TestPacketCountRX
CXP
R/W
8
-
0x00004038
ElectricalComplianceTest
CXP
R/W
4
-
IO Industries Inc.
www.ioindustries.com
Revision 2.0