2.5 Manual Programming Reference Chart
Command Name
Disable Users
0
00 #
ALL codes (except Master)
0M #
Manager of group M (from 1 to 6)
G0 #
All users in group G (from 1 to 6)
YES
GU #
User U (from 1 to 9) in group G (from 1 to 6)
YES
77 #
Service access code
YES
Activate Users
1
00 #
ALL codes (except Master)
0M #
Manager of group M (from 1 to 6)
G0 #
All users in group G (from 1 to 6)
YES
GU #
User U (from 1 to 9) in group G (from 1 to 6)
YES
77 #
Service access code
YES
Add/Modify Users
2
0M #
Manager of group M (from 1 to 6)
KKKKKKK #
Enter 7-digit code
GU #
User U (from 1 to 9) in group G (from 1 to 6)
KKK{KKK} #
Enter 3 to 6-digit code, same length as all
other access codes
YES
77 #
Service access code
KKK{KKK} #
Enter 3 to 6-digit code, same length as all
other access codes
YES
99 #
Master authorization code
MMMMMMM
Enter 8-digit code
M #
Re-enter 8-digit code to confirm
MMMMMMMM #
Delete Users
3
00 #
ALL codes (except Master)
0M #
Manager of group M (from 1 to 6)
G0 #
All users in group G (from 1 to 6)
YES
GU #
User U (from 1 to 9) in group G (from 1 to 6)
YES
77 #
Service access code
YES
Passage Mode
4
00 #
OFF (normal operation)
YES
01 #
ON (no code required to open door)
YES
Lock-out Mode
4
90 #
OFF (normal operation)
YES
91 #
ON (all user access codes temporarily locked out,
YES
Master and Manager codes still accepted for
programming)
Unlock Time Setup
5
SS #
Select from 01 to 20 seconds to turn the handle
after entering a valid code
Tamper Parameters Setup
6
MM #
Shutdown period, from 00 to 15; 00 = 30 sec,
1 to 15 = minutes
9N #
Tamper counter, from 3 to 6 invalid codes
prior to shutdown
Buzzer Volume Setup
7
00 #
OFF
0N #
Volume level control, from 1 to 9
Configuration Setup
8
00 #
Commercial configuration
01 #
Residential configuration
02 #
Handicapped configuration
Manual Diagnostics
9
30 #
Start Manual Diagnostics
123456789*0
Press each key in sequence to test the keypad.a
#
Passage Mode with Timer
9
41 #
Set timer for HH = 1 to 24 hours, 99 = no time limit.
HH #
The lock will enter Passage Mode immediately and return
to locked mode (normal operation) after the timer has elapsed.
YES
Privileged User Setup
9
5G #
Set all users in group G (from 1 to 6) as privileged
YES
9
6G #
Set all users in group G (from 1 to 6) as normal
YES
Factory Defaults
9
99 #
Restore factory default settings, erases all codes except
the Master code
Command
(1
st
digit)
Arguments
(2
nd
& 3
rd
digit )
Description
Available
to group
Manager