6.1 Comparison Operation Instructions
6.1.2 32-bit BIN data comparison
6-7
6
BA
S
IC
INSTRUCTIONS
D=,
D<>,
D<=,
D<,
D>=,
D>
D=,
D<>,
D<=,
D<,
D>=,
D>
(3) In the following program, the BIN value of
−
80000 is compared with the value in Var_D3
when M3 is ON, and Y33 turns ON when the value in Var_D3 is less than
−
80000, or when
M8 is ON.
[Structured ladder]
(4) In the following program, the value in Var_D0 is compared with the value in Var_D3, and Y33
turns ON when the value in Var_D3 is equal or greater than the value in Var_D0 or when
both M3 and M8 are ON.
[Structured ladder]