42
MIS-4220 / MIS-4220R / MIS-4230
43
Infinitely Expandable
5.14. Orion PDP Home Page logon and Version information
In order to move to Orion PDP's website, go to "Help" of menu bar → "OrionDisplay HomePage".
y
Orion PDP Home Page Logon
Go to "Help" of menu bar → "About" to check MSCS.
y
Checking MSCS Version
Protocol Form
1.
Send To PDP
Command
PDP ID
Sub
Command
Data
End
4byte
2byte
4byte
Variable
1byte
Format sent from PC to PDP, only the selected ID("PDP ID") will
-
correspond to the given command.
Receive From PDP
Command
PDP ID
Sub
Command
Data
End
4byte
2byte
4byte
Variable
1byte
A respond from PDP to PC, a respond format for certain
-
commands. Not all commands have response.
Sub Command
Command code
-
Data fomat
The format is 2byte dividing the Actual Data(1byte) into two, first
-
4bits("A") and second 4bits("B"), "B" adds 0x30, "A" shifts 4bit and
add 0x30. The Send Data(1byte) becomes 2byte.
1byte
-
0X6B
0X06
0X06 + 0X30
0X0B + 0X30
0X60
0X0B
Real Data
Send Data
0X36
0X3B
Protocol Value
2.
2.1 Command
Send To PDP
Send To PDP
ASCII
k(0x6B)
M(0x4D)
HEX
0x36
0x3B
0x34
0x3D
Starting code for Send Command from PC to PDP, fixed 4byte.
-
Refer to the Data format shown in 6.1 Protocol Form.
-
Receive From PDP
Receive From PDP
ASCII
k(0x6B)
N(0x4E)
HEX
0x36
0x3B
0x34
0x3E
Starting code for Send Respond from PDP to P, fixed 4byte.
-
Refer to the Data format shown in 6.1 Protocol Form.
-
0X6B
0X06
0X06 + 0X30
0X0B + 0X30
0X60
0X0B
Real Data
Send Data
0X36
0X3B
2.2 PDP ID
Format
Send Data is 2byte, Refer to the Data format shown in 6.1 Protocol
-
Form.
Ex)
-
ID value
Hex value
Send ID value
“1”
0x01
0x30, 0x31
“10”
0x0A
0x30, 0x3A
“20”
0x14
0x31, 0x34
“99”
0x63
0x36, 0x33
ID ="99" , example
-
99
0X63
0X06
0X06 + 0X30
0X03 + 0X30
0X60
0X03
Real Data
Send Data
0X36
0X33
ID ="99", Coding Example
-
//==========================================
PDP_ID = 99;
// PDP_ID: 0x63
ID[1] = ((PDP_ID)&0xF0>>4)+0x30;
// ID[1]: 0x36
ID[0] = (PDP_ID&0x0F)+0x30;
// ID[0]: 0x33
//==========================================
2.3 Sub Command
2.3.1 Multi Scale Control
Multi Scale Command
Multi Scale
ASCII
M(0x4D)
s(0x73)
HEX
0x34
0x3D
0x37
0x33
MPDP Multi Scale command
-
2.3.2 PDP Control
Power Command
Power On
ASCII
R(0x52)
n(0x6E)
HEX
0x35
0x32
0x36
0x3E
Power Off
ASCII
R(0x52)
f(0x66)
HEX
0x35
0x32
0x36
0x36
PDP Power On/Off command
-
Information OSD Command
Information OSD
ASCII
R(0x52)
I(0x49)
HEX
0x35
0x32
0x34
0x39
Command to display current input Mode, Resolution on OSD.
-
6. MSCS Protocol
*"BIC" function is applicable only to MIS-4230.
Downloaded From TV-Manual.com Manuals