xxxvii)GetModelID
Requests the revision of the dryer connected to the network node. This
request will return “L1V3_3”, indicating that the PNEUDRI electronic
Microprocessor dryer is operating with software version 3.3.
xxxviii)GetPressure
The inlet pressure to the dryer bank will be returned in millibar (gauge).
xxxix)GetPressureAFS
A “1” will be returned if Automatic Fault Shutdown (AFS) on the inle
pressure is activated.
xl)
GetQRV
A “1” will be returned if a Quick Repressurisation Valve (QRV) is fitted to
the dryer.
xli)
GetServiceDate
Requests the date on which the next service is due, the returned value
when converted to hexadecimal format will be from 010100 (01/01/00) to
1F0C6C (31/12/99).
xlii)
GetServiceDay
Requests the day on which the next service is due, the returned value will
be from 1 to 31.
xliii) GetServiceMonth
Requests the month during which the next service is due, the returned
value will be from 1 to 12.
xliv) GetServiceYear
Requests the year during which the next service is due, the returned value
will be from 0 to 99.
xlv)
GetSilencerDate
the date on which the next exhaust silencer change is due, the returned
value when converted to hexadecimal format will be from 010100
(01/01/00) to 1F0C6C (31/12/99).
xlvi) GetSilencerDay
Requests the day on which the next exhaust silencer change is due, the
returned value will be from 1 to 31.
24