PNU
Data type
Access Description
PMCtendo DD4
ASCII command
Actual values
1400
INTEGER32
ro
Actual position 20 bits/turn
PRD
1401
INTEGER32
ro
Speed
1402
INTEGER32
ro
Incremental position, actual value
1403
INTEGER32
ro
SI-position, actual value
PFB
1404
INTEGER32
ro
SI-velocity, actual value
PV
1405
INTEGER32
ro
SI contouring error
PE
1406
INTEGER32
ro
RMS current
I
1407
INTEGER32
ro
SI-speed, actual value
V
1408
INTEGER32
ro
Heatsink temperature
TEMPH
1409
INTEGER32
ro
Internal temperature
TEMPE
1410
INTEGER32
ro
DC-bus (DC-link) voltage
VBUS
1411
INTEGER32
ro
Ballast power
PBAL
1412
INTEGER32
ro
I
2
t - loading
I2T
1413
INTEGER32
ro
Running time
TRUN
Digital I/O configuration
1450
UINT32
r/w
Function of digital input 1
IN1MODE
1451
UINT32
r/w
Function of digital input 2
IN2MODE
1452
UINT32
r/w
Function of digital input 3
IN3MODE
1453
UINT32
r/w
Function of digital input 4
IN4MODE
1454
INTEGER32
r/w
Auxiliary variable for digital input 1
IN1TRIG
1455
INTEGER32
r/w
Auxiliary variable for digital input 2
IN2TRIG
1456
INTEGER32
r/w
Auxiliary variable for digital input 3
IN3TRIG
1457
INTEGER32
r/w
Auxiliary variable for digital input 4
IN4TRIG
1458
INTEGER32
r/w
Function of digital input 1
O1MODE
1459
INTEGER32
r/w
Function of digital input 2
O2MODE
1460
UINT32
r/w
Auxiliary variable for digital output 1
O1TRIG
1461
UINT32
r/w
Auxiliary variable for digital output 2
O2TRIG
1462
UINT32
r/w
State of four digital inputs, Enable,
2 digital outputs
STATIO
Analog configuration
1500
UINT32
r/w
Configuration of the analog input functions
ANCNFG
1501
UINT32
r/w
Configuration monitor function analog output 1
ANOUT1
1502
UINT32
r/w
Offset voltage for analog input 1
ANOFF1
1503
UINT32
r/w
Filter time constant for analog input 1
AVZ1
1504
UINT32
r/w
Scaling factor for velocity, analog input 1
VSCALE1
1505
UINT32
r/w
Scaling factor for current, analog input 1
ISCALE1
1506
UINT32
r/w
Configuration monitor function analog output 2
ANOUT2
1507
UINT32
r/w
Offset voltage for analog input 2
ANOFF2
1508
UINT32
r/w
Scaling factor for velocity, analog input 2
VSCALE2
1509
UINT32
r/w
Scaling factor for current, analog input 2
ISCALE2
Motor parameters
1550
UINT32
r/w
Brake configuration
MBRAKE
1551
UINT32
r/w
Motor number from motor database
MNUMBER
Manufacturer specific object channel
³
1600
Þ
p. 33 and description of the ASCII-commands on the CD-rom (4th quarter 2002).
Abbreviations in the “Access” column
The “Access” column shows which type of access (e.g read/write) is possible via the bus.
Abbrev.
Description
wo
“write only” access
ro
“read only” access
r/w
read/write access
User manual PROFIBUS DP PMCtendo DD4
Page 21
5 Using the parameter channel