Subindex
5
short description
read object format
Unit
—
Access
Read only
Data-type
see corresponding ASCII-command
Value range
see corresponding ASCII-command
Defaultvalue
—
EEPROM
—
Desription:
The following object formats are possible:
0
Function (no parameters – write only)
1
Function (32-Bit parameter)
2
Function (32-Bit parameter with weighting 3)
3
8-Bit integer
4
8-Bit unsigned integer
5
16-Bit integer
6
16-Bit unsigned integer
7
32-Bit integer
8
32-Bit unsigned integer
9
32-Bit integer (weighting 3)
Subindex
6
short description
read object control data
Unit
—
Access
Read only
Data-type
UNSIGNED32
Value range
0 ... 2
32
– 1
Defaultvalue
—
EEPROM
—
Description:
0x00010000 when altered, the variable has to be saved and the amplifier reset
0x00020000 variable will be saved in the serial EEPROM
0x00200000 variable is read-only, must not be written via PROFIBUS
Subindex
7,8
short description
reserved
Unit
—
Access
Read only
Data-type
UNSIGNED32
Value range
0 ... 2
32
- 1
Defaultvalue
—
EEPROM
—
Caution!
Objects with format 0 (subindex 5) must not be accessed reading
(response identification = 1)
Page 34
User manual PROFIBUS DP PMCtendo DD4
5 Using the parameter channel